PITFALLS IN THE DETERMINATION OF MAGNETIC-PERMEABILITY

被引:8
作者
BERNARDS, JPC
KUIPER, AET
DEWIT, HJ
VANDERIET, E
机构
[1] Philips Research Laboratories, Prof. Holstlaan 4
关键词
Magnetic variables measurement;
D O I
10.1109/20.334157
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Corection factors are provided for errors which may arise in permeability measurements. These errors are all related to the way the relative permeability is calculated from the raw data. After correction, measurements on differently shaped samples in different measurement geometries yield consistent permeability values.
引用
收藏
页码:4587 / 4589
页数:3
相关论文
共 4 条
[1]  
CRAIK DJ, 1971, STRUCTURE PROPERTIES, pCH1
[2]   DEMAGNETIZING FACTORS OF THE GENERAL ELLIPSOID [J].
OSBORN, JA .
PHYSICAL REVIEW, 1945, 67 (11-1) :351-357
[3]  
PURCELL EM, 1965, ELECTRICITY MAGNETIS, V2, P203
[4]  
STRATTON JA, 1941, ELECTROMAGNETIC THEO, P257