GAS-CHROMATOGRAPHY MASS-SPECTROMETRY METHODS FOR ANALYSIS OF 2-HYDROXYLATED AND 3-HYDROXYLATED FATTY-ACIDS - APPLICATION FOR ENDOTOXIN MEASUREMENT

被引:59
作者
MIELNICZUK, Z
MIELNICZUK, E
LARSSON, L
机构
[1] UNIV LUND, DEPT MED MICROBIOL, SOLVEGATAN 23, S-22362 LUND, SWEDEN
[2] CHILD HLTH CTR, WARSZAWA MIEDZYLESIE, POLAND
关键词
ENDOTOXIN; DUST; GCMS; HYDROXY ACID; ENVIRONMENT;
D O I
10.1016/0167-7012(93)90002-Y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Gas chromatography-mass Spectrometry (GC-MS) methods for analysis of 2- and 3-hydroxy fatty acids were evaluated. These acids were analysed as methyl-trimethylsilyl or methyl-pentafluorobenzoyl derivatives in the electron impact and chemical ionization-negative ion (NICI) modes, respectively. NICI spectra were strongly influenced by the temperature of the ion source. Both 2- and 3-hydroxylated acids with 10 18 carbon atoms were detected in organic dust collected from a ventilation duct; differential ion monitoring was used for their separation. The described GC-MS methods can be applied for determination of air-borne endotoxins.
引用
收藏
页码:91 / 102
页数:12
相关论文
共 17 条
[1]  
[Anonymous], 1988, MICROBIAL LIPIDS
[2]  
ASSELINEAU J, 1991, PROGR CHEM ORG NAT P, V56, P1
[3]   ACUTE BRONCHOCONSTRICTION INDUCED BY COTTON DUST - DOSE-RELATED RESPONSES TO ENDOTOXIN AND OTHER DUST FACTORS [J].
CASTELLAN, RM ;
OLENCHOCK, SA ;
HANKINSON, JL ;
MILLNER, PD ;
COCKE, JB ;
BRAGG, CK ;
PERKINS, HH ;
JACOBS, RR .
ANNALS OF INTERNAL MEDICINE, 1984, 101 (02) :157-163
[4]   INHALED ENDOTOXIN AND DECREASED SPIROMETRIC VALUES - AN EXPOSURE RESPONSE RELATION FOR COTTON DUST [J].
CASTELLAN, RM ;
OLENCHOCK, SA ;
KINSLEY, KB ;
HANKINSON, JL .
NEW ENGLAND JOURNAL OF MEDICINE, 1987, 317 (10) :605-610
[5]   HEALTH-EFFECTS OF EXPOSURE TO ENDOTOXINS AND ORGANIC DUST IN POULTRY SLAUGHTERHOUSE WORKERS [J].
HAGMAR, L ;
SCHUTZ, A ;
HALLBERG, T ;
SJOHOLM, A .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1990, 62 (02) :159-164
[6]   FALSE-POSITIVE RESULT IN LIMULUS TEST CAUSED BY LIMULUS AMEBOCYTE LYSATE-REACTIVE MATERIAL IN IMMUNOGLOBULIN PRODUCTS [J].
IKEMURA, K ;
IKEGAMI, K ;
SHIMAZU, T ;
YOSHIOKA, T ;
SUGIMOTO, T .
JOURNAL OF CLINICAL MICROBIOLOGY, 1989, 27 (09) :1965-1968
[7]  
KAWAI G, 1989, BIOCHIM BIOPHYS ACTA, V1001, P185
[8]   IDENTIFICATION OF 2-HYDROXY FATTY-ACIDS IN COMPLEX MIXTURES OF FATTY-ACID METHYL-ESTERS BY MASS CHROMATOGRAPHY [J].
LAINE, RA ;
YOUNG, ND ;
GERBER, JN ;
SWEELEY, CC .
BIOMEDICAL MASS SPECTROMETRY, 1974, 1 (01) :10-14
[9]   DETERMINATION OF LIPID-A AND ENDOTOXIN IN SERUM BY MASS-SPECTROSCOPY [J].
MAITRA, SK ;
SCHOTZ, MC ;
YOSHIKAWA, TT ;
GUZE, LB .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1978, 75 (08) :3993-3997
[10]   GAS-CHROMATOGRAPHY MASS-SPECTROMETRY OF LIPOPOLYSACCHARIDE 3-HYDROXY FATTY-ACIDS - COMPARISON OF PENTAFLUOROBENZOYL AND TRIMETHYLSILYL METHYL-ESTER DERIVATIVES [J].
MIELNICZUK, Z ;
ALUGUPALLI, S ;
MIELNICZUK, E ;
LARSSON, L .
JOURNAL OF CHROMATOGRAPHY, 1992, 623 (01) :115-122