EVALUATION OF AN ENHANCED DIGITAL FILM-DUPLICATION SYSTEM BY RECEIVER OPERATING CHARACTERISTIC ANALYSIS

被引:7
作者
HOFFMANN, KR
MACMAHON, H
DOI, KN
METZ, CE
YAO, L
ABE, K
机构
[1] Kurt Rossmann Laboratories for Radiologic Image Research, Department of Radiology, University of Chicago, Chicago, IL
关键词
DIAGNOSTIC RADIOLOGY; OBSERVER PERFORMANCE; RADIOGRAPHY; DIGITAL; LUNG NODULE; COMPARATIVE STUDIES;
D O I
10.1097/00004424-199312000-00010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Over- or underexposure often results in poor quality radiographs. Using receiver operating characteristic analysis, the authors investigated the potential utility of a system that corrects densities in such images to improve the accuracy of lung nodule detection. METHODS. Chest radiographs were digitized by a laser film digitizer. Simulated nodules were superimposed on 36 improperly exposed chest radiographs. All images, with and without nodules, were then processed by a nonlinear density-correction technique. Hard-copy images were produced by a laser film printer. Eight radiologists evaluated the corrected and uncorrected images for the presence or absence of lung nodules using a continuous (0-100) confidence-rating scale.
引用
收藏
页码:1134 / 1138
页数:5
相关论文
共 16 条
[1]   A FULLY AUTOMATED ADAPTIVE UNSHARP MASKING TECHNIQUE IN DIGITAL CHEST RADIOGRAPH [J].
ABE, K ;
KATSURAGAWA, S ;
SASAKI, Y ;
YANAGISAWA, T .
INVESTIGATIVE RADIOLOGY, 1992, 27 (01) :64-70
[2]  
DOI K, 1985, PROGR MED RAD PHYSIC, V11, P181
[3]  
EDWARDS AL, 1954, STATISTICAL METHODS, P246
[4]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY .3. AUTOMATED DETECTION OF NODULES IN PERIPHERAL LUNG FIELDS [J].
GIGER, ML ;
DOI, K ;
MACMAHON, H .
MEDICAL PHYSICS, 1988, 15 (02) :158-166
[5]   INVESTIGATION OF BASIC IMAGING PROPERTIES IN DIGITAL RADIOGRAPHY .3. EFFECT OF PIXEL SIZE ON SNR AND THRESHOLD CONTRAST [J].
GIGER, ML ;
DOI, K .
MEDICAL PHYSICS, 1985, 12 (02) :201-208
[6]   A COMPARISON OF PHYSICAL IMAGE QUALITY INDEXES AND OBSERVER PERFORMANCE IN THE RADIOGRAPHIC DETECTION OF NYLON BEADS [J].
LOO, LND ;
DOI, K ;
METZ, CE .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (07) :837-856
[7]   DIGITAL RADIOGRAPHY OF SUBTLE PULMONARY ABNORMALITIES - AN ROC STUDY OF THE EFFECT OF PIXEL SIZE ON OBSERVER PERFORMANCE [J].
MACMAHON, H ;
VYBORNY, CJ ;
METZ, CE ;
DOI, K ;
SABETI, V ;
SOLOMON, SL .
RADIOLOGY, 1986, 158 (01) :21-26
[8]   THE NATURE AND SUBTLETY OF ABNORMAL FINDINGS IN CHEST RADIOGRAPHS [J].
MACMAHON, H ;
MONTNER, SM ;
DOI, K ;
LIU, KJM .
MEDICAL PHYSICS, 1991, 18 (02) :206-210
[9]   DIGITAL CHEST RADIOGRAPHY - EFFECT ON DIAGNOSTIC-ACCURACY OF HARD COPY, CONVENTIONAL VIDEO, AND REVERSED GRAY SCALE VIDEO DISPLAY FORMATS [J].
MACMAHON, H ;
METZ, CE ;
DOI, K ;
KIM, T ;
GIGER, ML ;
CHAN, HP .
RADIOLOGY, 1988, 168 (03) :669-673
[10]   BASIC PRINCIPLES OF ROC ANALYSIS [J].
METZ, CE .
SEMINARS IN NUCLEAR MEDICINE, 1978, 8 (04) :283-298