MODIFICATION OF THE ISO-SHUNT LINES FOR LOW INSPIRED OXYGEN CONCENTRATIONS

被引:16
作者
PETROS, AJ
DORE, CJ
NUNN, JF
机构
[1] CLIN RES CTR,DIV ANAESTHESIA,HARROW HA1 3UJ,MIDDX,ENGLAND
[2] CLIN RES CTR,DIV MED STAT,HARROW HA1 3UJ,MIDDX,ENGLAND
[3] NORTHWICK PK HOSP & CLIN RES CTR,HARROW HA1 3UJ,MIDDX,ENGLAND
关键词
LUNG; GAS EXCHANGE; SHUNTING;
D O I
10.1093/bja/72.5.515
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Arterial PO2 (Pa-O2) has been related to inspired oxygen concentration (FIO2 range 0.21-0.60) in 20 patients, breathing spontaneously, while recovering from a range of conditions treated in an intensive therapy unit. There was a highly significant linear trend (P < 0.001) for the mean venous admixture (''virtual shunt''), calculated from the iso-shunt diagram (model A), to increase from 0.11 to 0.19 as FIO2 decreased from 0.60 to 0.21. As this appeared to be caused by relative ventilation/perfusion (V/Q) mismatch, we prepared a second model (model B) with a variable two-compartment relative V/Q mismatch in addition to a shunt. Regression of the degree of mismatch on the shunt gave good agreement between predicted and observed Pa-O2 values (mean bias -0.17 kPa, pooled within patient SD 1.22). Model B is now proposed to extend the applicability of the iso-shunt diagram for FIO2 values less than 0.35. Published postoperative Pa-O2 data from other workers showed good agreement with our final model (mean bias 0.10 kPa, pooled SD 0.41). The new diagram may therefore have wide applicability in the field of anaesthesia and intensive care.
引用
收藏
页码:515 / 522
页数:8
相关论文
共 14 条
[1]  
Adair GS, 1925, J BIOL CHEM, V63, P529
[2]  
[Anonymous], 1977, BIOENGINEERING ASPEC
[3]   USE OF ISO-SHUNT LINES FOR CONTROL OF OXYGEN-THERAPY [J].
BENATAR, SR ;
HEWLETT, AM ;
NUNN, JF .
BRITISH JOURNAL OF ANAESTHESIA, 1973, 45 (07) :711-718
[4]   OXYGEN-THERAPY AFTER ABDOMINAL-SURGERY [J].
DRUMMOND, GB ;
WRIGHT, DJ .
BRITISH JOURNAL OF ANAESTHESIA, 1977, 49 (08) :789-797
[5]   OXYGEN AND CARBON-MONOXIDE CAPACITIES OF FETAL AND ADULT BLOOD [J].
GREGORY, IC .
JOURNAL OF PHYSIOLOGY-LONDON, 1974, 236 (03) :625-634
[6]   NOMOGRAMS FOR CORRECTION OF BLOOD PO2, PCO2, PH AND BASE EXCESS FOR TIME AND TEMPERATURE [J].
KELMAN, GR ;
NUNN, JF .
JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (05) :1484-&
[8]   A REASSESSMENT OF THE VALIDITY OF THE ISO-SHUNT GRAPH [J].
LAWLER, PGP ;
NUNN, JF .
BRITISH JOURNAL OF ANAESTHESIA, 1984, 56 (12) :1325-1335
[9]  
NUNN JF, 1987, APPLIED RESPIRATORY
[10]  
Severinghaus J W, 1978, Acta Anaesthesiol Scand Suppl, V68, P9