THE [C-13]ACETATE BREATH TEST ACCURATELY REFLECTS GASTRIC-EMPTYING OF LIQUIDS IN BOTH LIQUID AND SEMISOLID TEST MEALS

被引:258
作者
BRADEN, B
ADAMS, S
DUAN, LP
ORTH, KH
MAUL, FD
LEMBCKE, B
HOR, G
CASPARY, WF
机构
[1] UNIV FRANKFURT,DEPT NUCL MED,D-60590 FRANKFURT,GERMANY
[2] COMMUNITY HOSP,SOLINGEN,GERMANY
关键词
D O I
10.1016/0016-5085(95)90202-3
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims: The current standard for gastric emptying studies are radioactive isotope methods. [C-13]breath tests have been developed as a nonradioactive alternative. the aim of this study was to validate a [C-13]acetate breath test as a measure of gastric emptying of the liquid phase both in liquid and semisolid test meals by simultaneous radioscintigraphy. Methods: Thirty-five patients with dyspeptic symptoms and 20 healthy volunteers were tested using a semisolid oatmeal or a liquid test meal. Both test meats were labeled by 150 mg sodium [C-13]acetate and (in patients) by 45 MBq Tc-99m-albumin colloid. Half-time of gastric emptying was calculated after curve fitting of the C-13 exhalation to a modified power exponential function. Tc-99m-albumin emptying was measured by conventional radioscintigraphy. Results:The half-emp tying times for the [C-13]acetate breath test closely correlated to those measured by radioscintigraphy both for semisolids (r = 0.87) and liquids (r = 0.95). The time of maximum (CO2)-C-13 exhalation was itself a reliable parameter compared with the half-emptying times obtained by scintigraphy (r = 0.85 for semisolids; r = 0.94 for liquids). Conclusions: The [C-13]acetate breath test is a reliable and noninvasive tool for the analysis of gastric emptying rates of liquid phases without radiation exposure.
引用
收藏
页码:1048 / 1055
页数:8
相关论文
共 23 条
[1]  
BJORKMAN DJ, 1991, AM J GASTROENTEROL, V86, P821
[2]  
BRADEN B, 1994, Z GASTROENTEROL, V32, P675
[3]   VARIABILITY OF GASTRIC-EMPTYING MEASUREMENTS IN MAN EMPLOYING STANDARDIZED RADIOLABELED MEALS [J].
BROPHY, CM ;
MOORE, JG ;
CHRISTIAN, PE ;
EGGER, MJ ;
TAYLOR, AT .
DIGESTIVE DISEASES AND SCIENCES, 1986, 31 (08) :799-806
[4]   GASTRIC-EMPTYING IN NORMAL SUBJECTS - A REPRODUCIBLE TECHNIQUE USING A SINGLE SCINTILLATION CAMERA AND COMPUTER-SYSTEM [J].
COLLINS, PJ ;
HOROWITZ, M ;
COOK, DJ ;
HARDING, PE ;
SHEARMAN, DJC .
GUT, 1983, 24 (12) :1117-1125
[5]   GASTRIC-ACID SECRETION AND GASTRIC-EMPTYING OF LIQUIDS IN 99 MALE DUODENAL-ULCER PATIENTS [J].
CORINALDESI, R ;
STANGHELLINI, V ;
PAPARO, GF ;
PATERNICO, A ;
RUSTICALI, AG ;
BARBARA, L .
DIGESTIVE DISEASES AND SCIENCES, 1989, 34 (02) :251-256
[6]  
FRIED R, 1993, GASTROENTEROLOGY, V104, pA509
[7]   MEASUREMENT OF GASTRIC-EMPTYING RATE OF SOLIDS BY MEANS OF A CARBON-LABELED OCTANOIC-ACID BREATH TEST [J].
GHOOS, YF ;
MAES, BD ;
GEYPENS, BJ ;
MYS, G ;
HIELE, MI ;
RUTGEERTS, PJ ;
VANTRAPPEN, G .
GASTROENTEROLOGY, 1993, 104 (06) :1640-1647
[8]   PATIENT MOTION ARTIFACTS ON SCINTIGRAPHIC GASTRIC-EMPTYING STUDIES [J].
GLOWNIAK, JV ;
WAHL, RL .
RADIOLOGY, 1985, 154 (02) :537-538
[9]   GEOMETRIC METHOD FOR MEASURING BODY-SURFACE AREA - HEIGHT-WEIGHT FORMULA VALIDATED IN INFANTS, CHILDREN, AND ADULTS [J].
HAYCOCK, GB ;
SCHWARTZ, GJ ;
WISOTSKY, DH .
JOURNAL OF PEDIATRICS, 1978, 93 (01) :62-66
[10]   RELATIONSHIP OF THE MOTOR-ACTIVITY OF THE ANTRUM, PYLORUS, AND DUODENUM TO GASTRIC-EMPTYING OF A SOLID-LIQUID MIXED MEAL [J].
HOUGHTON, LA ;
READ, NW ;
HEDDLE, R ;
HOROWITZ, M ;
COLLINS, PJ ;
CHATTERTON, B ;
DENT, J .
GASTROENTEROLOGY, 1988, 94 (06) :1285-1291