MECHANISM OF OZONE GENERATION IN AIR-FED OZONIZERS

被引:184
作者
YAGI, S
TANAKA, M
机构
[1] Products Dev. Lab., Mitsubishi Electric Corp., Amagasaki, Hyogo
关键词
D O I
10.1088/0022-3727/12/9/013
中图分类号
O59 [应用物理学];
学科分类号
摘要
The mechanism of ozone generation in the silent discharge of air-fed ozonisers is studied theoretically and experimentally. The nitrogen oxides (NOx) formed in the silent discharge have been found to play an important role in the process of ozone generation due to the catalytic cycle for O3 destruction: NO+O3 to NO2+O2 and NO2+O to NO+O2. Taking this catalytic cycle into account, a mechanism is proposed to explain the characteristics of ozone generation in air-fed ozonisers. The electron impact dissociation coefficients of O 2, N2 and O3 and the gas temperature in the silent discharge are estimated by the computer matching of the theoretical calculations to experimental results.
引用
收藏
页码:1509 / 1520
页数:12
相关论文
共 12 条
[1]  
BAULCH DL, 1973, CHEMICAL KINETICS DA, V5, P49
[2]  
BENSON SW, 1959, OZONE CHEM TECHNOLOG, P405
[3]   MECHANISM OF OZONE FORMATION IN THE SILENT ELECTRIC DISCHARGE [J].
DEVINS, JC .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1956, 103 (08) :460-466
[4]  
HAMPSON RF, 1975, NBSIR74430
[5]   ON THE NATURE OF SILENT ELECTRIC DISCHARGE [J].
HONDA, K ;
NAITO, Y .
JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1955, 10 (11) :1007-1011
[6]  
LUNT RW, 1959, OZONE CHEMISTRY TECH, P286
[7]  
TABATA N, 1977, T IEE JAPAN B, V97, P665
[8]  
TABATA N, 1977, T IEE JAPAN B, V97, P100
[9]  
Tanaka M., 1978, T IEE JAPAN, V98A, P57
[10]  
YAGI S, 1976, T IEE JAPAN B, V96, P569