TENSILE AND VISCOELASTIC PROPERTIES OF HUMAN PATELLAR TENDON

被引:299
作者
JOHNSON, GA [1 ]
TRAMAGLINI, DM [1 ]
LEVINE, RE [1 ]
OHNO, K [1 ]
CHOI, NY [1 ]
WOO, SLY [1 ]
机构
[1] UNIV PITTSBURGH,DEPT ORTHOPAED SURG,MUSCULOSKELETAL RES CTR,PITTSBURGH,PA 15213
关键词
D O I
10.1002/jor.1100120607
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The tensile and viscoelastic properties of fresh-frozen, nonirradiated human patellar tendon were investigated in two groups of 15 specimens: one group was from individuals 29-50 years old and the other group was from individuals 64-93 years old. The central portion of each patella-patellar tendon-tibia complex was subjected to cyclic preconditioning, stress-relaxation, cyclic stress-relaxation, and load to failure tests. For each age group, stress-relaxation and stress-strain curves were obtained, from which percentage relaxation, ultimate tensile strength, strain at failure, modulus, and strain energy density were determined. Viscoelastic behavior was described with use of quasilinear viscoelasticity. The younger group showed a 46 +/- 9% (mean +/- SD) decrease in stress after 15 minutes, whereas the older group exhibited a 50 +/- 6% decrease. The values for ultimate tensile strength and strain at failure, respectively, were 64.7 C 15.0 MPa and 14 +/- 6% for the younger group and 53.6 +/- 10.0 MPa and 15 +/- 5% for the older group. Modulus values were 660 +/- 266 MPa for the younger group and 504 +/- 222 MPa for the older group. Except for ultimate tensile strength, which was 17% less for the older group than for the younger one, no statistically significant differences were found in tensile or viscoelastic properties. This study indicated that there were minimal differences in biomechanical properties of the substance of the patellar tendon between younger and older age groups.
引用
收藏
页码:796 / 803
页数:8
相关论文
共 26 条
[1]  
BLEVINS FT, 1993, FEB ANN M AM ORTH SO
[2]   EFFECTS OF STRUCTURE AND STRAIN-MEASUREMENT TECHNIQUE ON THE MATERIAL PROPERTIES OF YOUNG HUMAN TENDONS AND FASCIA [J].
BUTLER, DL ;
GROOD, ES ;
NOYES, FR ;
ZERNICKE, RF ;
BRACKETT, K .
JOURNAL OF BIOMECHANICS, 1984, 17 (08) :579-596
[3]   COMPARISON OF MATERIAL PROPERTIES IN FASCICLE-BONE UNITS FROM HUMAN PATELLAR TENDON AND KNEE LIGAMENTS [J].
BUTLER, DL ;
KAY, MD ;
STOUFFER, DC .
JOURNAL OF BIOMECHANICS, 1986, 19 (06) :425-432
[4]  
CARSON W G JR, 1991, Arthroscopy, V7, P368, DOI 10.1016/0749-8063(91)90006-J
[5]  
Fithian D.C., 1990, CLIN ORTHOP RELAT R, P19
[6]  
France E P, 1988, PROSTHETIC LIGAMENT, V180, P185
[7]  
FRIEDMAN MJ, 1985, CLIN ORTHOP RELAT R, V196, P9
[8]  
FUNG YC, 1972, BIOMECHANICS ITS FDN, P181
[9]  
GRAF BK, 1992, T ORTHOP RES SOC, V17, P147
[10]   CONSTITUTIVE EQUATION FOR COLLAGEN FIBERS [J].
HAUT, RC ;
LITTLE, RW .
JOURNAL OF BIOMECHANICS, 1972, 5 (05) :423-&