A NEW 2-CHAMBER-MODEL FOR EXAMINATION AND DEMONSTRATION OF TRANSDURAL LIQUOR LEAKAGE AFTER SPINAL-ANESTHESIA

被引:4
作者
ENK, D [1 ]
ENK, E [1 ]
机构
[1] UNIV MUNSTER,ANASTHESIOL & OPERAT INTENS MED KLIN & POLIKLIN,W-4400 MUNSTER,GERMANY
来源
ANAESTHESIST | 1995年 / 44卷 / 11期
关键词
SPINAL ANESTHESIA; 2-CHAMBER MODEL; LIQUOR LEAKAGE; POST-DURAL-PUNCTURE TRAUMA; RETRACTION;
D O I
10.1007/s001010050211
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Various in vitro models have been introduced for comparative examinations of post-dural-puncture trauma and measurement of liquor leakage through puncture sites. These models allow simulation of subarachnoid, but not of peridural, pressure. A new two-chamber-model realizes the simulation of both subarachnoid and peridural pressure and allows observation of in vitro punctures with video-documentation. Frame grabbing and (computer-aided) image analysis show new aspects of spinal puncture effects. Therefore, postdural-puncture trauma and retraction can be objectively visualized by this method, which has not previously been demonstrated. Methods. The two-chamber-model consists of two short aluminium cylinders. Native human dura patches (8 x 8 mm) from fresh cadavers are put (correctly oriented) between two special polyamide seals. Mounted between the upper and lower cylinder, these seals stretch the dura patch, which remains flexible and even in all directions. After filling of the lower (subarachnoid) and upper (peridural) chamber with Ringer lactate solution, positive or negative physiological pressure can be adjusted by way of two (Ringer lactate solution filled) infusion lines in each chamber. Puncturing is performed at an angle of 57 degrees to the dura. The model allows examination with epi-illumination and transmitted (polarized) light. In vitro punctures are observed through an inverted camera lens with an CCD-Hi8 video camera (Canon UClHi) looking into the peridural chamber and documentated by means of an S-VHS video recorder (Panasonic NV-FS200EG). After true-colour frame grabbing by a video digitizer (Fast Screen Machine II), single video frames can be optimized and analysed with a 486-66 MHz computer and conventional software (Corel Draw 3.0, Photostyler 1.1 a, DDL Aequitas 1.00 b). Punctures demonstrated in this paper have been done under simulation of a transdural gradient of 20 cm water similar to the situation of a recumbent patient (15 cm water in the subarachnoid and -5 cm water in the peridural chamber). The punctures were followed by short-time observation for up to 10 minutes. Results. By making it possible to obtain a picture of the puncture site at 20-ms intervals (because of the PAL norm of 50 half-frames/s), video-documentation has become accepted as superior to conventional photography. When the Ringer lactate solution in the subarachnoid chamber is stained with methylene blue, transdural leakage can easily be observed. The results of this documentation technique demonstrate that no dural puncture can be atraumatic, when a 29-G Quincke needle is used. Calculation of the difference between a digitized video frame before and after the puncture clearly illustrates the dural trauma. Owing to their non-cutting tip, as expected, pencil-point needles leave diffuse changes across the dura patch, whereas a more local trauma was observed after puncturing with cutting-tip needles. The same computer calculation between two video frames allows examination of post-puncture-dural retraction of the puncture site. In this connection, we found that relevant dural retraction is a phenomenon limited to the first minute after puncture. Thin spinal needles with so-called modern tips (e.g. Whitacre, Atraucan) can minimize the post-dural-puncture trauma, whereas thicker, conventional, spinal needles (Quincke) leave considerable dural defects. Conclusions. The two-chamber model presented allows easy simulation of physiological subarachnoid and peridural pressure. The Ringer lactate solution in the subarachnoid chamber corresponds to the liquor, whereas that in the peridural chamber corresponds to the intercellular (peridural) space. The tension of the dural patch between the polyamide seals is similar to the situation in an anatomical model observed by spinaloscopy (in an earlier study). With the video documentation and computer-aided analysis technique introduced, dural trauma and retraction on the puncture site can be examined and demonstrated precisely. This model can be regarded as the current experimental standard for comparative in vitro studies of different spinal needles.
引用
收藏
页码:761 / 769
页数:9
相关论文
共 13 条
[1]  
CELLENO D, 1993, REGION ANESTH, V18, P218
[2]   FLUID-FLOW THROUGH DURAL PUNCTURE SITES - AN INVITRO COMPARISON OF NEEDLE POINT TYPES [J].
CRUICKSHANK, RH ;
HOPKINSON, JM .
ANAESTHESIA, 1989, 44 (05) :415-418
[3]   ANATOMICAL RE-EVALUATION OF LUMBAR DURA MATER WITH REGARD TO POSTSPINAL HEADACHE - EFFECT OF DURAL PUNCTURE [J].
DITTMANN, M ;
SCHAFER, HG ;
ULRICH, J ;
BONDTAYLOR, W .
ANAESTHESIA, 1988, 43 (08) :635-637
[4]   POSTDURAL PUNCTURE HEADACHE IN YOUNG-PATIENTS - A COMPARATIVE-STUDY BETWEEN THE USE OF 0.52 MM (25-GAUGE) AND 0.33 MM (29-GAUGE) SPINAL NEEDLES [J].
GEURTS, JW ;
HAANSCHOTEN, MC ;
VANWIJK, RM ;
KRAAK, H ;
BESSE, TC .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1990, 34 (05) :350-353
[5]  
GIELEN M, 1989, REGION ANESTH, V14, P101
[6]   FLUID-FLOW THROUGH DURAL PUNCTURE SITES [J].
JANES, EF ;
PENNEFATHER, S ;
WILKINSON, K .
ANAESTHESIA, 1989, 44 (12) :1011-1011
[7]  
KREUSCHER H, 1989, Regional-Anaesthesie, V12, P43
[8]  
MOLLMANN M, 1992, ANAESTHESIST, V41, P685
[9]  
READY LB, 1989, ANESTH ANALG, V69, P457
[10]  
READY LB, 1985, ANESTHESIOLOGY, V63, pA241