DETERMINATION OF PESTICIDES IN WATER BY CAPILLARY GAS-CHROMATOGRAPHY WITH SPLITLESS INJECTION OF LARGE-SAMPLE VOLUMES

被引:18
作者
SUZUKI, T
YAGUCHI, K
OHNISHI, K
YAMAGISHI, T
机构
[1] Tama Branch Laboratory, Tokyo Metropolitan Research Laboratory of Public Health, Tachikawa-shi, Tokyo, 190, 3-16-25, Shibazaki-cho
关键词
D O I
10.1016/0021-9673(94)85303-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A large-volume injection for a capillary gas chromatograph equipped with an electron-capture, nitrogen-phosphorus-selective (NPD) or flame photometric detector is proposed for the determination of pesticides. The cold-trap column, a deactivated fused-silica column (3 m x 0.53 mm I.D.), was attached to the analytical column (30 m) and the regulation column (3 cm), DB-5, both of 0.25 mm I.D. with film thickness 0.25 mu m, with a dual-outlet splitter. The regulation column was connected with the solvent-diversion column, a deactivated fused-silica column (2 m x 0.53 mm I.D.), which was led out of the column oven and attached to an electromagnetic valve. By opening the valve in the splitless mode, the pesticides slowly injected in n-hexane in a volume from 25 to 150 mu l were trapped in the cold-trap column, and a large volume of n-hexane was almost all diverted from the gas chromatograph through the diversion column. The trapped pesticides were introduced to the analytical column by closing the valve. Twenty-five pesticides, scattered on a golf course in Japan, were determined at concentrations from 1 to 100 ng/ml in. n-hexane. The reproducibility of separation of the pesticides by the proposed method was similar to that of normal splitless (1-mu l) injection. The proposed method was applied to the screening of the pesticides in groundwater after liquid-liquid extraction with dichloromethane; the pesticides could be determined at levels lower than 1 mu g/l in a 20-ml water sample.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 14 条
  • [1] SORPTION CAPACITIES OF GRAPHITIZED CARBON-BLACK IN DETERMINATION OF CHLORINATE PESTICIDE TRACES IN WATER
    BACALONI, A
    GORETTI, G
    LAGANA, A
    PETRONIO, BM
    ROTATORI, M
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (13) : 2033 - 2036
  • [2] ONLINE FRACTIONATION AND IDENTIFICATION OF DIESEL FUEL POLYCYCLIC AROMATIC-COMPOUNDS BY TWO-DIMENSIONAL MICROBORE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CAPILLARY GAS-CHROMATOGRAPHY
    DAVIES, IL
    BARTLE, KD
    WILLIAMS, PT
    ANDREWS, GE
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (03) : 204 - 209
  • [3] SPECIFIC IDENTIFICATION OF SYNTHETIC ORGANIC-CHEMICALS IN RIVER WATER USING LIQUID LIQUID EXTRACTION AND RESIN ADSORPTION COUPLED WITH ELECTRON-IMPACT, CHEMICAL IONIZATION AND ACCURATE MASS MEASUREMENT GAS-CHROMATOGRAPHY MASS-SPECTROMETRY ANALYSES
    DIETRICH, AM
    MILLINGTON, DS
    SEO, YH
    [J]. JOURNAL OF CHROMATOGRAPHY, 1988, 436 (02): : 229 - 241
  • [4] GROB K, 1992, HRC-J HIGH RES CHROM, V15, P715
  • [5] GROB K, 1992, HRC-J HIGH RES CHROM, V15, P659
  • [6] HILLER JF, 1993, J HIGH RES CHROMATOG, V16, P5
  • [7] LEE HB, 1986, J ASSOC OFF ANA CHEM, V69, P568
  • [8] LOPEZAVILA V, 1985, ANAL CHEM, V57, P2979
  • [9] LIQUID-CHROMATOGRAPHIC TRACE ENRICHMENT WITH ONLINE CAPILLARY GAS-CHROMATOGRAPHY FOR THE DETERMINATION OF ORGANIC POLLUTANTS IN AQUEOUS SAMPLES
    NOROOZIAN, E
    MARIS, FA
    NIELEN, MWF
    FREI, RW
    DEJONG, GJ
    BRINKMAN, UAT
    [J]. JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (01): : 17 - 24
  • [10] ONLINE COMBINATION OF LIQUID-CHROMATOGRAPHY AND CAPILLARY GAS-CHROMATOGRAPHY - PRECONCENTRATION AND ANALYSIS OF ORGANIC-COMPOUNDS IN AQUEOUS SAMPLES
    NOY, T
    WEISS, E
    HERPS, T
    VANCRUCHTEN, H
    RIJKS, J
    [J]. JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (02): : 181 - 186