SIZE-EXCLUSION CHROMATOGRAPHY DIMENSION FOR ROD-LIKE MACROMOLECULES

被引:17
作者
DUBIN, PL [1 ]
KAPLAN, JI [1 ]
TIAN, BS [1 ]
MEHTA, M [1 ]
机构
[1] INDIANA UNIV PURDUE UNIV,DEPT PHYS,INDIANAPOLIS,IN 46205
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 515卷
关键词
D O I
10.1016/S0021-9673(01)89299-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A phenomenological approach has been taken to determine the macromolecular dimension that controls peak migration in size-exclusion chromatography. For macromolecules representative of the class of rigid rods, flexible rods, random coils, and compact ellipsoids, the dependence of the chromatographic partition coefficient, KSEC, on the viscosity radius, the radius of gyration, and the contour length, respectively, was determined. Since none of these dimensions appears to control retention uniquely, a phenomenological definition of RSEC was provided. This parameter progressively deviates from the hydrodynamic radius with increasing macromolecular asymmetry. © 1990.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 13 条
[1]  
Ackers G. K., 1975, PROTEINS, V1, P1
[2]   COMMENTS ON EXCLUSION OF POLYMER-CHAINS FROM SMALL PORES AND ITS RELATION TO GEL-PERMEATION CHROMATOGRAPHY [J].
CASASSA, EF .
MACROMOLECULES, 1976, 9 (01) :182-185
[3]   THEORETICAL MODELS FOR PEAK MIGRATION IN GEL PERMEATION CHROMATOGRAPHY [J].
CASASSA, EF .
JOURNAL OF PHYSICAL CHEMISTRY, 1971, 75 (26) :3929-+
[4]  
CASSASSA EF, 1969, MACROMOLECULES, V2, P14
[5]   INFLUENCE OF IONIC-STRENGTH AND COMPOSITION ON THE SIZE OF MIXED MICELLES OF SODIUM DODECYL-SULFATE AND TRITON-X-100 [J].
DUBIN, PL ;
PRINCIPI, JM ;
SMITH, BA ;
FALLON, MA .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1989, 127 (02) :558-565
[6]   OPTIMIZATION OF SIZE-EXCLUSION SEPARATION OF PROTEINS ON A SUPEROSE COLUMN [J].
DUBIN, PL ;
PRINCIPI, JM .
JOURNAL OF CHROMATOGRAPHY, 1989, 479 (01) :159-164
[7]   FAILURE OF UNIVERSAL CALIBRATION FOR SIZE EXCLUSION CHROMATOGRAPHY OF RODLIKE MACROMOLECULES VERSUS RANDOM COILS AND GLOBULAR-PROTEINS [J].
DUBIN, PL ;
PRINCIPI, JM .
MACROMOLECULES, 1989, 22 (04) :1891-1896
[8]   DISPARITY BETWEEN STOKES RADII OF DEXTRANS AND PROTEINS AS DETERMINED BY RETENTION VOLUME IN GEL-PERMEATION CHROMATOGRAPHY [J].
FRIGON, RP ;
LEYPOLDT, JK ;
UYEJI, S ;
HENDERSON, LW .
ANALYTICAL CHEMISTRY, 1983, 55 (08) :1349-1354
[9]  
GIDDINGS JC, 1968, J PHYS CHEM-US, V78, P397
[10]   A UNIVERSAL CALIBRATION FOR GEL PERMEATION CHROMATOGRAPHY [J].
GRUBISIC, Z ;
REMPP, P ;
BENOIT, H .
JOURNAL OF POLYMER SCIENCE PART B-POLYMER LETTERS, 1967, 5 (9PB) :753-&