EXPERIMENTAL STUDIES ON ARTIFICIAL-VENTILATION USING A TIDAL VOLUME VENTILATOR - MECHANICS AND DYNAMICS OF VENTILATION

被引:7
作者
LINDAHL, S [1 ]
OKMIAN, L [1 ]
机构
[1] UNIV LUND HOSP,DEPT PAEDIAT SURG,S-22185 LUND,SWEDEN
关键词
D O I
10.1111/j.1399-6576.1979.tb01463.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
In 24 piglets (2.7–24.5 kg b.w.), the mechanics of ventilation, the accuracy of dosage of respiratory volumes, and the influence of the ventilator's volume/ pressure characteristics (Cvent “internal compliance”) on the dynamic course of insufflations were studied. A linear relationship was shown to exist between tidal volume and end‐aspiratory tracheal pressure and between tidal volume and insufflation time. The insufflation time was reduced to about 50% of previously registered values. The error between set and registered tidal volume was found to be 6.0 ± 2.7%. During the insufflation a linear relationship was found between the instant amount of delivered breathing gas and the corresponding endotracheal pressure change. The ventilator's Cven did (and body size, total compliance and tidal volume did not) significantly influence the size of the direction coefficient for the linear instantaneous volume/pressure relationship, the magnitude of tracheal peak pressure and the duration of the insufflation. A low Cvent resulted in a high peak pressure and a short insufflation time, and vice versa. The use of greater power from the ventilator resulted in a significant shortening of the duration of insufflation and vice versa. The duration of insufflation is the parameter of choice in evaluating the efficiency of the ventilatory equipment. When the ventilator's performance is defined, measurements of the duration of insufflation may enable evaluation of conditions within the lungs. © 1979 The Scandinavian Society of Anaesthesiologists
引用
收藏
页码:359 / 369
页数:11
相关论文
共 26 条
[1]  
BAKER AB, 1971, THESIS MAGDALEN COLL
[2]   EFFECTS OF VARYING RESPIRATORY WAVEFORMS ON GAS EXCHANGE [J].
BERGMAN, NA .
ANESTHESIOLOGY, 1967, 28 (02) :390-&
[3]  
COURNAND A, 1948, AM J PHYSIOL, V152, P162
[4]  
ENGSTROM CG, 1963, ACTA ANAESTH SCA S13
[5]   RELIABILITY OF PNEUMOTACHOGRAPHY IN RESPIRATOR VENTILATION - AN EXPERIMENTAL STUDY [J].
GRENVIK, A ;
HEDSTRAND, U .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1966, 10 (03) :157-+
[6]   VENTILATION OF A LUNG MODEL WITH ENGSTROM RESPIRATOR - EFFECT OF DIFFERENT RESPIRATOR SETTINGS ON GAS DISTRIBUTION [J].
HEDENSTIERNA, G ;
JOHANSSON, H .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1972, 16 (04) :206-215
[7]   EFFECT OF CHANGES IN TIDAL VENTILATION ON PHYSIOLOGIC SHUNTING [J].
HEDLEYWHYTE, J ;
LAVER, MB ;
BENDIXEN, HH .
AMERICAN JOURNAL OF PHYSIOLOGY, 1964, 206 (04) :891-&
[8]  
HERZOG P, 1968, OPUS MED STOCKH, V1
[9]  
JANSSON L, 1972, SCAND J RESPIR DIS, V53, P237
[10]   EFFECTS ON BREATHING MECHANICS AND GAS-EXCHANGE OF DIFFERENT INSPIRATORY GAS-FLOW PATTERNS DURING ANESTHESIA [J].
JOHANSSON, H ;
LOFSTROM, JB .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1975, 19 (01) :8-18