SELECTIVE PRECONCENTRATION FOR CAPILLARY ZONE ELECTROPHORESIS USING PROTEIN-G IMMUNOAFFINITY CAPILLARY CHROMATOGRAPHY

被引:71
作者
COLE, LJ [1 ]
KENNEDY, RT [1 ]
机构
[1] UNIV FLORIDA, DEPT CHEM, GAINESVILLE, FL 32611 USA
关键词
CAPILLARY ELECTROPHORESIS; PRECONCENTRATION; IMMUNOAFFINITY CHROMATOGRAPHY; PERFUSION CHROMATOGRAPHY;
D O I
10.1002/elps.1150160190
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capillaries with 150 mu m inner diameter were packed with a perfused protein G chromatographic support and used as immunoaffinity preconcentrators for capillary zone electrophoresis. Antibody was loaded onto the protein G support to form an immunoaffinity stationary phase. Injection of samples onto the column caused selective retention and preconcentration of antigen. Injection of appropriate buffers onto the column caused desorption of the antibody and antigen which were then separated by capillary zone electrophoresis. The combination was used on-line and off-line. For on-line combination, a flow-gated interface coupled the two columns and allowed injection of desorbed zones onto the electrophoresis system. Off-line coupling required collection of desorbed fractions and then injection onto the electrophoresis system. Flow rates as high as 100 mu L/min were used to load sample onto the affinity column. Desorbing flow rates had to be 1 mu L/min or less to prevent excessive dilution during desorption. Using the system, 1 mt insulin samples could be loaded onto the affinity column and desorbed in volumes as small as 1 mu L for 1000-fold preconcentration. The use of the preconcentrator with serum samples spiked with insulin was demonstrated.
引用
收藏
页码:549 / 556
页数:8
相关论文
共 33 条
[1]   FLOW-THROUGH PARTICLES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BIOMOLECULES - PERFUSION CHROMATOGRAPHY [J].
AFEYAN, NB ;
GORDON, NF ;
MAZSAROFF, I ;
VARADY, L ;
FULTON, SP ;
YANG, YB ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01) :1-29
[2]   AUTOMATED REAL-TIME IMMUNOASSAY OF BIOMOLECULES [J].
AFEYAN, NB ;
GORDON, NF ;
REGNIER, FE .
NATURE, 1992, 358 (6387) :603-604
[3]  
AKERSTROM B, 1985, J IMMUNOL, V135, P2589
[4]   IMPROVEMENT IN THE METHOD OF SAMPLE STACKING FOR GRAVITY INJECTION IN CAPILLARY ZONE ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL BIOCHEMISTRY, 1992, 202 (02) :306-309
[5]   OPTIMIZATION IN SAMPLE STACKING FOR HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :2042-2047
[6]   ONLINE PRECONCENTRATION OF TRIAZINE HERBICIDES WITH TANDEM OCTADECYL CAPILLARIES-CAPILLARY ZONE ELECTROPHORESIS [J].
CAI, J ;
ELRASSI, Z .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (6-7) :1179-1192
[7]   SELECTIVE ONLINE PRECONCENTRATION OF PROTEINS BY TANDEM METAL CHELATE-CAPILLARIES CAPILLARY-ZONE ELECTROPHORESIS [J].
CAI, JY ;
ELRASSI, Z .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (9-10) :2007-2024
[8]   SWITCHING VALVE WITH INTERNAL MICRO PRECOLUMN FOR ONLINE SAMPLE ENRICHMENT IN CAPILLARY ZONE ELECTROPHORESIS [J].
DEBETS, AJJ ;
MAZEREEUW, M ;
VOOGT, WH ;
VANIPEREN, DJ ;
LINGEMAN, H ;
HUPE, KP ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1992, 608 (1-2) :151-158
[9]   TANDEM CHROMATOGRAPHIC-IMMUNOLOGICAL ANALYSES [J].
DEFRUTOS, M ;
REGNIER, FE .
ANALYTICAL CHEMISTRY, 1993, 65 (01) :A17-&
[10]  
DOLNIK V, 1990, J MICROCOLUMN SEP, V2, P229