SCREENING OF RENAL-ARTERY STENOSIS - EARLY RESULTS OF COLOR DOPPLER SONOGRAPHY

被引:12
作者
BREITENSEHER, M [1 ]
KAINBERGER, F [1 ]
HUBSCH, P [1 ]
TRATTNIG, S [1 ]
BALDT, M [1 ]
BARTON, P [1 ]
KARNEL, F [1 ]
机构
[1] UNIV VIENNA,RADIODIAGNOST KLIN,A-1010 VIENNA,AUSTRIA
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1992年 / 156卷 / 03期
关键词
HYPERTENSION; RENOVASCULAR; RENAL ARTERIES; STENOSIS OR OBSTRUCTION; KIDNEY; BLOOD SUPPLY; US STUDIES; RENAL ANGIOGRAPHY;
D O I
10.1055/s-2008-1032873
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The value of colour Doppler sonography in the diagnosis of renal artery stenosis has been studied retrospectively. 17 patients were examined (34 main renal arteries and 7 accessory renal arteries; ages 37 to 84 years; 7 males and 10 females). We studied 1) ability to study the main renal arteries, 2) visibility of accessory renal arteries and 3) the sensitivity and specificity of colour Doppler sonography for the diagnosis of renal artery stenosis. The results were compared with intraarterial angiography. Demonstration of the main renal arteries with colour Doppler sonography was possible in 23 of the 34 vessels. Not a single of the 7 accessory renal arteries was demonstrated by colour Doppler sonography. Of 8 angiographically demonstrated stenoses (more than 50 % narrowing) 2 were missed by colour Doppler sonography. One stenosis was correctly diagnosed and 5 were incorrectly evaluated by sonography. 16 out of 18 angiographically normal main renal arteries were correctly evaluated by colour Doppler sonography but 2 showed a false positive finding. This results in a sensitivity of 17 % and a specificity of 89 % per kidney. Colour Doppler sonography cannot be recommended as a screening method for renal artery stenosis in view of its limited accuracy.
引用
收藏
页码:228 / 231
页数:4
相关论文
共 19 条
  • [1] NONINVASIVE DIAGNOSIS OF RENAL-ARTERY STENOSIS BY ECHO-DOPPLER VELOCIMETRY
    AVASTHI, PS
    VOYLES, WF
    GREENE, ER
    [J]. KIDNEY INTERNATIONAL, 1984, 25 (05) : 824 - 829
  • [2] RENAL-ARTERY STENOSIS - PROSPECTIVE EVALUATION OF DIAGNOSIS WITH COLOR DUPLEX US COMPARED WITH ANGIOGRAPHY - WORK IN PROGRESS
    BERLAND, LL
    KOSLIN, DB
    ROUTH, WD
    KELLER, FS
    [J]. RADIOLOGY, 1990, 174 (02) : 421 - 423
  • [3] BLAUFOX MD, 1989, SEMIN NUCL MED, V19, P116
  • [4] DAVIS G, 1966, VARIATION RENAL BLOO
  • [5] RENAL-ARTERY STENOSIS - EVALUATION WITH COLOR DOPPLER FLOW IMAGING
    DESBERG, AL
    PAUSHTER, DM
    LAMMERT, GK
    HALE, JC
    TROY, RB
    NOVICK, AC
    NALLY, JV
    WELTEVREDEN, AM
    [J]. RADIOLOGY, 1990, 177 (03) : 749 - 753
  • [6] COLOR-CODED DUPLEX SONOGRAPHY AND ULTRASOUND CONTRAST-MEDIA - DEMONSTRATION OF PERIPHERAL RENAL PERFUSION DEFECTS IN AN ANIMAL-EXPERIMENT
    FOBBE, F
    SIEGERT, J
    FRITZSCH, T
    KOCH, HC
    WOLF, KJ
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 154 (03): : 242 - 245
  • [7] HAVEY RJ, 1985, JAMA-J AM MED ASSOC, V254, P388, DOI 10.1001/jama.254.3.388
  • [8] PHANTOM EXAMINATIONS WITH SONOGRAPHIC CONTRAST AGENTS TO IMPROVE COLOR-CODED DOPPLER SONOGRAPHY (ANGIODYNOGRAPHY) OF THE A-FEMORALIS SUPERFICIALIS IN THE ADDUCTOR CANAL
    HENDRICKX, P
    BRASSEL, F
    ROTH, U
    FROEHLICH, H
    WAGNER, HH
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 154 (01): : 34 - 38
  • [9] JAGER K, 1991, INTERNIST, V32, P127
  • [10] KOHLER TR, 1986, J VASC SURG, V4, P450