POSITRON EMISSION TOMOGRAPHY WITH A LARGE AXIAL ACCEPTANCE ANGLE - SIGNAL-TO-NOISE CONSIDERATIONS

被引:10
作者
KARP, JS [1 ]
KINAHAN, PE [1 ]
MANKOFF, DA [1 ]
机构
[1] UNIV WASHINGTON,DEPT MED,SEATTLE,WA 98195
关键词
D O I
10.1109/42.97572
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A volume imaging PET scanner with a large acceptance angle, such as the PENN-PET, offers fine spatial sampling and resolution in three dimensions, and a high sensitivity because of the inclusion of all cross-plane rays. The signal-to-noise ratio (SNR) is used to evaluate image quality for different scanning conditions of the PENN-PET using an activated cylindrical phantom with cold spheres of various sizes. Raising the energy threshold to 400 keV improves the SNR by lowering the scatter fraction, even though it also reduces the sensitivity. Increasing the axial acceptance angle from +/- 1.3-degrees to +/- 6.5-degrees also improves the SNR by increasing the sensitivity, even with a two-dimensional reconstruction algorithm, which comprises spatial resolution in the axial direction for points at the edge of the radial field of view. Initial results show that a three-dimensional reconstruction offers an improved SNR over a two-dimensional reconstruction that does not use all cross-plane rays.
引用
收藏
页码:249 / 255
页数:7
相关论文
共 22 条
[1]   CORRECTION FOR SCATTERED RADIATION IN A RING DETECTOR POSITRON CAMERA BY INTEGRAL TRANSFORMATION OF THE PROJECTIONS [J].
BERGSTROM, M ;
ERIKSSON, L ;
BOHM, C ;
BLOMQVIST, G ;
LITTON, J .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (01) :42-50
[2]  
BURNHAM CA, 1988, IEEE T NUCL SCI, V35, P676
[3]   SPHERICAL POSITRON EMISSION TOMOGRAPH (S-PET) I - PERFORMANCE ANALYSIS [J].
CHO, ZH ;
HONG, KS ;
HILAL, SK .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (02) :422-438
[4]   FULLY 3-DIMENSIONAL POSITRON EMISSION TOMOGRAPHY [J].
COLSHER, JG .
PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (01) :103-115
[5]  
DAUBEWITHERSPOON ME, 1987, J NUCL MED, V28, P1717
[6]   3-DIMENSIONAL IMAGE-RECONSTRUCTION FROM COMPLETE PROJECTIONS [J].
DEFRISE, M ;
TOWNSEND, DW ;
CLACK, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (05) :573-587
[7]  
DERENZO SE, 1980, J NUCL MED, V21, P971
[8]  
KARP JS, 1990, J NUCL MED, V31, P617
[9]   CONSTRAINED FOURIER SPACE METHOD FOR COMPENSATION OF MISSING DATA IN EMISSION COMPUTED-TOMOGRAPHY [J].
KARP, JS ;
MUEHLLEHNER, G ;
LEWITT, RM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (01) :21-25
[10]   ANALYTIC 3D IMAGE-RECONSTRUCTION USING ALL DETECTED EVENTS [J].
KINAHAN, PE ;
ROGERS, JG .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :964-968