THE APPROPRIATENESS OF USE OF CORONARY ANGIOGRAPHY IN NEW-YORK-STATE

被引:108
作者
BERNSTEIN, SJ
HILBORNE, LH
LEAPE, LL
FISKE, ME
PARK, RE
KAMBERG, CJ
BROOK, RH
机构
[1] UNIV CALIF LOS ANGELES, SCH MED, DEPT MED, LOS ANGELES, CA USA
[2] UNIV CALIF LOS ANGELES, SCH MED, DEPT PATHOL & LAB MED, LOS ANGELES, CA USA
[3] UNIV CALIF LOS ANGELES, SCH PUBL HLTH, LOS ANGELES, CA USA
[4] UNIV MICHIGAN, SCH MED, ANN ARBOR, MI 48104 USA
[5] UNIV MICHIGAN, SCH PUBL HLTH, ANN ARBOR, MI 48109 USA
[6] HARVARD UNIV, SCH PUBL HLTH, BOSTON, MA 02115 USA
来源
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION | 1993年 / 269卷 / 06期
关键词
D O I
10.1001/jama.269.6.766
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective.-To determine the appropriateness of use of coronary angiography in New York State. Design.-Retrospective randomized medical record review. Setting.-Fifteen randomly selected hospitals in New York State that provide coronary angiography. Patients.-Random sample of 1335 patients undergoing coronary angiography in New York State in 1990. Main Outcome Measures.-Percentage of patients who underwent coronary angiography for appropriate, uncertain, or inappropriate indications. Results.-Approximately 76% of coronary angiographies were rated appropriate; 20%, uncertain; and 4%, inappropriate. Inappropriate use did not vary significantly between the elderly (ie, patients aged 65 years and older) and nonelderly, 4.7% and 3.9%, respectively. Although the rate of inappropriate use varied from 0% to 9% among hospitals, the difference was not significant. Rates of appropriateness did not vary by hospital location (upstate vs downstate), volume (fewer than 750 procedures annually or at least 750 procedures annually), teaching status, or whether revascularization was available at the hospital where angiography was performed. Conclusions.-Although coronary angiography was used for few inappropriate indications in New York State, many procedures were performed for uncertain indications in which the benefit and risk were approximately equal or unknown.
引用
收藏
页码:766 / 769
页数:4
相关论文
共 14 条
  • [1] BERNSTEIN SJ, 1992, JRA03 PUBL
  • [2] BERNSTEIN SJ, IN PRESS INT J TECHN
  • [3] HOW CORONARY ANGIOGRAPHY IS USED - CLINICAL DETERMINANTS OF APPROPRIATENESS
    CHASSIN, MR
    KOSECOFF, J
    SOLOMON, DH
    BROOK, RH
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1987, 258 (18): : 2543 - 2547
  • [4] DOES INAPPROPRIATE USE EXPLAIN GEOGRAPHIC VARIATIONS IN THE USE OF HEALTH-CARE SERVICES - A STUDY OF 3 PROCEDURES
    CHASSIN, MR
    KOSECOFF, J
    PARK, RE
    WINSLOW, CM
    KAHN, KL
    MERRICK, NJ
    KEESEY, J
    FINK, A
    SOLOMON, DH
    BROOK, RH
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1987, 258 (18): : 2533 - 2537
  • [5] Cochran WG., 1963, SAMPLING TECHNIQUES, V2nd ed
  • [7] RESULTS OF A 2ND-OPINION TRIAL AMONG PATIENTS RECOMMENDED FOR CORONARY ANGIOGRAPHY
    GRABOYS, TB
    BIEGELSEN, B
    LAMPERT, S
    BLATT, CM
    LOWN, B
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1992, 268 (18): : 2537 - 2540
  • [8] AUDIT OF CORONARY ANGIOGRAPHY AND BYPASS-SURGERY
    GRAY, D
    HAMPTON, JR
    BERNSTEIN, SJ
    KOSECOFF, J
    BROOK, RH
    [J]. LANCET, 1990, 335 (8701) : 1317 - 1320
  • [9] THE APPROPRIATENESS OF USE OF PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY IN NEW-YORK-STATE
    HILBORNE, LH
    LEAPE, LL
    BERNSTEIN, SJ
    PARK, RE
    FISKE, ME
    KAMBERG, CJ
    ROTH, CP
    BROOK, RH
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 269 (06): : 761 - 765
  • [10] HUBER PJ, 1967, 5TH P BERK S MATH ST, V1, P221