MEASUREMENT OF HIP PROSTHESES USING IMAGE-ANALYSIS - THE MAXIMA HIP TECHNIQUE

被引:54
作者
HARDINGE, K [1 ]
PORTER, ML [1 ]
JONES, PR [1 ]
HUKINS, DWL [1 ]
TAYLOR, CJ [1 ]
机构
[1] UNIV MANCHESTER,DEPT MED BIOPHYS,MANCHESTER M13 9PT,LANCS,ENGLAND
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1991年 / 73卷 / 05期
关键词
D O I
10.1302/0301-620X.73B5.1894658
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A computer-based image analysis system has been developed as a research tool in total hip replacement. The system has been programmed to take multiple measurements from coronal plane radiographs. Poor quality radiographic images can be enhanced and standardised. The measurements which can be obtained include stem subsidence, cup migration, cup wear, and stem loosening. Reproducibility and accuracy were +/- 0.01 mm and +/- 0.5 mm respectively. The present application is in retrospective research, but prospective monitoring of radiographs is planned.
引用
收藏
页码:724 / 728
页数:5
相关论文
共 15 条
[1]  
BALLARD DH, 1982, COMPUTER VISION, P64
[2]  
BECHTOLD JE, 1986, ORTHOP CLIN N AM, V17, P605
[3]  
BRAND RA, 1986, CLIN ORTHOP RELAT R, V210, P185
[4]  
DAVIS DN, 1991, IN PRESS BR J ORTHOD
[5]   A REVIEW ON BIOMEDICAL IMAGE-PROCESSING AND FUTURE-TRENDS [J].
DHAWAN, AP .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1990, 31 (3-4) :141-183
[6]  
HERZENBERG JE, 1988, ORTHOPEDICS, V11, P1549
[8]   Prosthetic hip failure: Preliminary findings of retrospective radiograph image analysis [J].
Jones, P.R. ;
Taylor, C.J. ;
Hukins, D.W.L. ;
Hardinge, K. ;
Porter, M.L. .
Engineering in Medicine, 1988, 17 (03) :119-125
[9]   PROSTHETIC HIP FAILURE - RETROSPECTIVE RADIOGRAPH IMAGE-ANALYSIS OF THE ACETABULAR CUP [J].
JONES, PR ;
TAYLOR, CJ ;
HUKINS, DWL ;
PORTER, ML ;
HARDINGE, K .
JOURNAL OF BIOMEDICAL ENGINEERING, 1989, 11 (03) :253-257
[10]  
LOEBL J, 1985, IMAGE ANAL PRINCIPLE, P87