MEASUREMENTS OF COMPRESSIBILITY FACTOR AND VAPOR-PRESSURE FOR REFRIGERANT 502

被引:6
作者
KIMURA, T [1 ]
UEMATSU, M [1 ]
WATANABE, K [1 ]
机构
[1] KEIO UNIV,DEPT MECH ENGN,YOKOHAMA,KANAGAWA 223,JAPAN
关键词
D O I
10.1021/je00024a001
中图分类号
O414.1 [热力学];
学科分类号
摘要
The compressibility factors and vapor pressure have been measured on Refrigerant 502 by using a Burnett apparatus. Refrigerant 502 is a minimum-boiling azeotrope of Refrigerant 22 (CHClF//2) and Refrigerant 115 (CClF//2CF//3). The results on the compressibility factor cover the range of temperatures from 273 to 383 K and of pressures from 0. 12 to 12. 3 MPa corresponding to a pressures from 0. 12 to 12. 3 MPa corresponding to a density variation from 4 to 1035 kg/m**3. The experimental uncertainity of these 149 results was estimated to be plus or minus 0. 2%. Twenty-five measurements of vapor pressure were made for temperatures from 273 to 354 K with an experimental uncertainty of plus or minus 0. 05%. A correlation of vapor pressures was proposed for temperatures from 170 to 355 K.
引用
收藏
页码:109 / 112
页数:4
相关论文
共 11 条
[1]  
BADYLKES IS, 1964, KHOLOD TEKH, P41
[2]  
DENEMOURS EID, CITED INDIRECTLY
[3]  
DORING R, 1975, 14TH P INT I REFR, P196
[4]  
LOFFLER HJ, 1967, KALTETECHNIK, V19, P201
[5]  
LONG LJ, CITED INDIRECTLY
[6]  
Martin JJ, 1970, ASHRAE T, V76, P129
[7]  
TODOROVIC M, 1972, KLIMAT GREJ HLAD, V1, P2
[8]  
TODOROVIC M, 1971, SAOPSTENJA TERMOTEHN, P2
[9]  
WAKAMATSU S, 1976, THESIS TOKYO METROPO
[10]  
WATANABE K, 1977, 7TH P S THERM PROP A, P470