SIMULTANEOUS CALCULATION OF FLOW AND DIFFUSION SENSITIVITY IN STEADY-STATE FREE PRECESSION IMAGING

被引:27
作者
GUDBJARTSSON, H
PATZ, S
机构
[1] MIT,BRIGHAM & WOMENS HOSP,DEPT RADIOL,DEPT ELECT ENGN & COMP SCI,BOSTON,MA 02115
[2] HARVARD UNIV,SCH MED,BOSTON,MA
关键词
FLOW; DIFFUSION; SSFP; SIMULATION;
D O I
10.1002/mrm.1910340413
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this paper the authors quantitatively evaluate the combined effect of both flow and diffusion in steady-state free precession (SSFP) imaging. A partition analysis (PA) is used to derive a fourth order approximation (in E(2)) of the signal in an echo SSFP sequence. The authors also introduce a novel very fast simulation technique, based on a circular convolution, which accurately accounts for both flow and diffusion, A 2D SSFP-echo sequence was implemented to obtain experimental data from a phantom containing three different solutions. Excellent agreement between the theory and the experimental data was found. Then by using the simulation algorithm and experimental measurements of in vivo brain motion, the authors estimated the artifacts to be expected in SSFP diffusion imaging of the brain and found them to be comparable with those of pulsed gradient spin echo, Finally, the authors point out the equivalence between the flow sensitivity of SSFP and RF spoiling commonly used in fast imaging.
引用
收藏
页码:567 / 579
页数:13
相关论文
共 39 条
[1]   ANALYSIS AND CORRECTION OF MOTION ARTIFACTS IN-DIFFUSION WEIGHTED IMAGING [J].
ANDERSON, AW ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :379-387
[2]   THE DIFFUSION SENSITIVITY OF FAST STEADY-STATE FREE PRECESSION IMAGING [J].
BUXTON, RB .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (02) :235-243
[3]   ANALYTICAL SOLUTION AND VERIFICATION OF DIFFUSION EFFECT IN SSFP [J].
CARNEY, CE ;
WONG, STS ;
PATZ, S .
MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) :240-246
[4]   EFFECTS OF DIFFUSION ON FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE EXPERIMENTS [J].
CARR, HY ;
PURCELL, EM .
PHYSICAL REVIEW, 1954, 94 (03) :630-638
[5]   ELIMINATION OF TRANSVERSE COHERENCES IN FLASH MRI [J].
CRAWLEY, AP ;
WOOD, ML ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (03) :248-260
[6]   APPLICATION OF FOURIER TRANSFORM SPECTROSCOPY TO MAGNETIC RESONANCE [J].
ERNST, RR ;
ANDERSON, WA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1966, 37 (01) :93-+
[7]   PHASE AND INTENSITY ANOMALIES IN FOURIER TRANSFORM NMR [J].
FREEMAN, R ;
HILL, HDW .
JOURNAL OF MAGNETIC RESONANCE, 1971, 4 (03) :366-&
[8]   THE STEADY-STATE SIGNALS IN SHORT-REPETITION-TIME SEQUENCES [J].
GYNGELL, ML .
JOURNAL OF MAGNETIC RESONANCE, 1989, 81 (03) :474-483
[9]   FAST IMAGING OF CSF FLOW MOTION PATTERNS USING STEADY-STATE FREE PRECESSION (SSFP) [J].
JOLESZ, FA ;
PATZ, S ;
HAWKES, RC ;
LOPEZ, I .
INVESTIGATIVE RADIOLOGY, 1987, 22 (10) :761-771
[10]   DIFFUSION AND FIELD-GRADIENT EFFECTS IN NMR FOURIER SPECTROSCOPY [J].
KAISER, R ;
BARTHOLDI, E ;
ERNST, RR .
JOURNAL OF CHEMICAL PHYSICS, 1974, 60 (08) :2966-2979