FINE-NEEDLE ASPIRATION BIOPSY FOR CYTOPATHOLOGIC ANALYSIS - UTILITY OF SYRINGE HANDLES, AUTOMATED GUNS, AND THE NONSUCTION METHOD

被引:31
作者
HOPPER, KD
ABENDROTH, CS
STURTZ, KW
MATTHEWS, YL
SHIRK, SJ
机构
[1] PENN STATE UNIV,MILTON S HERSHEY MED CTR,DEPT PATHOL,HERSHEY,PA 17033
[2] PENN STATE UNIV,MILTON S HERSHEY MED CTR,DEPT BIOSTAT & EPIDEMIOL,HERSHEY,PA 17033
关键词
BIOPSIES; TECHNOLOGY; KIDNEY; BIOPSY; LIVER; PANCREAS;
D O I
10.1148/radiology.185.3.1438769
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The performances of seven techniques and devices used with 22-gauge needles to obtain biopsy specimens for cytologic analysis were compared by means of single-blinded evaluation with an objective, previously published grading scheme. A total of 420 specimens were obtained from 10 fresh human cadavers (42 specimens per cadaver), including 30 hepatic, 20 renal, and 10 pancreatic specimens per technique or device. No statistical differences existed in the liver, kidney, or pancreas or in the combined data in the performance of the aspirator gun, syringe holders, vacuum needle, and end-cut gun versus the manual aspiration biopsy technique performed with a 22-gauge Chiba needle. However, nonaspiration, fine-needle capillary biopsy (FNCB) performed statistically significantly worse than any other technique or device in the kidney and pancreas and in comparison with the overall combined data. In the liver, no statistically significant difference existed in the overall performance of FNCB versus conventional aspiration biopsy, but the amount of cellular material obtained with FNCB was statistically significantly less.
引用
收藏
页码:819 / 824
页数:6
相关论文
共 27 条
[1]  
ABELE JS, 1983, ARCH SURG-CHICAGO, V118, P859
[2]   FINE-NEEDLE BIOPSY - COMPARISON OF CELLULAR YIELD WITH AND WITHOUT ASPIRATION [J].
AKHTAR, M ;
ALI, MA ;
HUQ, M ;
FAULKNER, C .
DIAGNOSTIC CYTOPATHOLOGY, 1989, 5 (02) :162-165
[3]  
BRIFFOD M, 1982, ACTA CYTOL, V26, P195
[4]   PREOPERATIVE DIAGNOSIS IN CARCINOMA OF BREAST [J].
DAVIES, CJ ;
ELSTON, CW ;
COTTON, RE ;
BLAMEY, RW .
BRITISH JOURNAL OF SURGERY, 1977, 64 (05) :326-328
[5]  
DIXON JM, 1983, LANCET, V2, P564
[6]   FINE NEEDLE ASPIRATION CYTOLOGY, IN RELATIONSHIPS TO CLINICAL EXAMINATION AND MAMMOGRAPHY IN THE DIAGNOSIS OF A SOLID BREAST MASS [J].
DIXON, JM ;
ANDERSON, TJ ;
LAMB, J ;
NIXON, SJ ;
FORREST, APM .
BRITISH JOURNAL OF SURGERY, 1984, 71 (08) :593-596
[7]   NEEDLE ASPIRATION OF THE BREAST WITH IMMEDIATE REPORTING OF MATERIAL [J].
DUGUID, HLD ;
WOOD, RAB ;
IRVING, AD ;
PREECE, PE ;
CUSCHIERI, A .
BRITISH MEDICAL JOURNAL, 1979, 2 (6183) :185-187
[8]   NONASPIRATION FINE-NEEDLE CYTOLOGY OF THE LIVER - A NEW TECHNIQUE FOR OBTAINING DIAGNOSTIC SAMPLES [J].
FAGELMAN, D ;
CHESS, Q .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (06) :1217-1219
[9]   FINE-NEEDLE ASPIRATION BIOPSY - A REVIEW [J].
FRABLE, WJ .
HUMAN PATHOLOGY, 1983, 14 (01) :9-28
[10]  
FRUNIVAL CM, 1975, LANCET, V2, P446