FLOW-INJECTION ANALYSIS OF L-LACTATE WITH ENZYME AMPLIFICATION AND AMPEROMETRIC DETECTION

被引:40
作者
ASOUZU, MU [1 ]
NONIDEZ, WK [1 ]
HO, MH [1 ]
机构
[1] UNIV ALABAMA,DEPT CHEM,BIRMINGHAM,AL 35294
关键词
D O I
10.1021/ac00206a012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow Injection analysis method for the determination of the lactate anion with enzyme amplification and amperometric detection is described. The system utilizes an oxygen electrode for measurement of changes in the oxygen concentration In the flow stream. Two enzymes, lactate oxidase and lactate dehydrogenase, were randomly colmmobillzed on aminopropyl controlled-pore glass (AMP-CPG) and packed into a reactor. ß-NADH was used as a coenzyme for the regeneration of lactate from pyruvate. The experimental conditions for the determination of the lactate anion were studied for this system by the simplex and the univariant methods. The results obtained under these two conditions were compared. The simplex experimental condition yielded a calibration curve whose linear portion had a slope that was 1.2 times greater than that of the linear portion of the curve obtained under univariant conditions. The limit of detection under simplex condition was 1.19 ✕ 10−7 M vs 3.29 ✕ 10−7 M lactate under unlvariant conditions. The relative standard deviation obtained for this system at 6 ✕ 10−6 M lactate (n = 10) was about 2.5% under simplex conditions and 3.6% under unlvariant maximization conditions. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:708 / 712
页数:5
相关论文
共 19 条
[1]  
BERGMEYER H, 1987, METHOD ENZYMATIC ANA, V1
[2]   IMMOBILIZED ENZYMES - CATALYTIC PROPERTIES OF LACTATE-DEHYDROGENASE COVALENTLY ATTACHED TO GLASS BEADS [J].
DIXON, JE ;
STOLZENBACH, FE ;
BERENSON, JA ;
KAPLAN, NO .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1973, 52 (03) :905-912
[3]   ELECTROCHEMICAL BIOSENSORS [J].
FREW, JE ;
HILL, HAO .
ANALYTICAL CHEMISTRY, 1987, 59 (15) :A933-&
[4]   ENZYME AMPLIFICATION LASER FLUORIMETRY [J].
IMASAKA, T ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1979, 51 (13) :2082-2085
[5]   A FAST HIGHLY SENSITIVE COLORIMETRIC ENZYME-IMMUNOASSAY SYSTEM DEMONSTRATING BENEFITS OF ENZYME AMPLIFICATION IN CLINICAL-CHEMISTRY [J].
JOHANNSSON, A ;
STANLEY, CJ ;
SELF, CH .
CLINICA CHIMICA ACTA, 1985, 148 (02) :119-124
[6]  
JOHANSSON A, 1985, J IMMUNOL METHODS, V83, P89
[7]  
KULYS JJ, 1986, BIOSENSORS, V2, P3
[8]  
MCCOMB RB, 1976, CLIN CHEM, V22, P141
[9]   CATALYTIC ASSAY OF L-LACTATE OR PYRUVATE WITH AN ENZYME ELECTRODE BASED ON IMMOBILIZED LACTATE OXIDASE AND LACTATE-DEHYDROGENASE [J].
MIZUTANI, F ;
SHIMURA, Y ;
TSUDA, K .
CHEMISTRY LETTERS, 1984, (02) :199-202
[10]  
MOTTOLA HA, 1980, ANAL CHEM, V52, P2332