IMPROVED APPARATUS FOR NEUTRON-CAPTURE THERAPY OF RAT-BRAIN TUMORS

被引:16
作者
LIU, HYB
JOEL, DD
SLATKIN, DN
CODERRE, JA
机构
[1] Medical Department, Brookhaven National Laboratory, Upton
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1994年 / 28卷 / 05期
关键词
BROOKHAVEN MEDICAL RESEARCH REACTOR; NCT; RAT; BRAIN TUMOR; COLLIMATOR;
D O I
10.1016/0360-3016(94)90491-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The assembly for irradiating tumors in the rat brain at the thermal neutron beam port of the Brookhaven Medical Research Reactor was redesigned to lower the average whole-body dose from different components of concomitant radiation without changing the thermal neutron fluence at the brain tumor. Methods and Materials: At present, the tumor-bearing rat is positioned in a rat holder that functions as a whole-body radiation shield. A 2.54 cm-thick collimator with a centered conical aperture, 6 cm diameter tapering to 2 cm diameter, is used to restrict the size of the thermal neutron field. Using the present holder and collimator as a baseline design, Monte Carlo calculations and mixed-field dosimetry were used to assess new designs. Results: The computations indicate that a 0.5 cm-thick plate, made of (Li2CO3)-Li-6 dispersed in polyethylene (Li-poly), instead of the existing rat holder, will reduce the whole-body radiation dose. Other computations show that a 10.16 cm-thick (4 inches) Li-poly collimator, having a centered conical aperture of 12 cm diameter tapering to 2 cm diameter, would further reduce the whole-body dose. Conclusion: The proposed irradiation apparatus of tumors in the rat brain, although requiring a 2.3-fold longer irradiation time, would reduce the average whole-body dose to less than half of that from the existing irradiation assembly.
引用
收藏
页码:1167 / 1173
页数:7
相关论文
共 7 条
[1]  
BARTH RF, 1990, CANCER RES, V50, P1061
[2]  
BRIESMEISTER JF, 1986, MCNP GENERAL MONTE C
[3]   DERIVATIONS OF RELATIVE BIOLOGICAL EFFECTIVENESS FOR THE HIGH-LET RADIATIONS PRODUCED DURING BORON NEUTRON-CAPTURE IRRADIATIONS OF THE 9L RAT GLIOSARCOMA IN-VITRO AND IN-VIVO [J].
CODERRE, JA ;
MAKAR, MS ;
MICCA, PL ;
NAWROCKY, MM ;
LIU, HYB ;
JOEL, DD ;
SLATKIN, DN ;
AMOLS, HI .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (05) :1121-1129
[4]   COMPARISON OF MEASURED PARAMETERS FROM A 24-KEV AND A BROAD-SPECTRUM EPITHERMAL NEUTRON BEAM FOR NEUTRON-CAPTURE THERAPY - AN IDENTIFICATION OF CONSEQUENTIAL PARAMETERS [J].
FAIRCHILD, RG ;
SARAF, SK ;
KALEFEZRA, J ;
LASTER, BH .
MEDICAL PHYSICS, 1990, 17 (06) :1045-1052
[5]   BORON NEUTRON-CAPTURE THERAPY OF INTRACEREBRAL RAT GLIOSARCOMAS [J].
JOEL, DD ;
FAIRCHILD, RG ;
LAISSUE, JA ;
SARAF, SK ;
KALEFEZRA, JA ;
SLATKIN, DN .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (24) :9808-9812
[6]  
SARAF SK, 1990, NEUTRON BEAM DESIGN, P307
[7]  
SLATKIN DN, 1990, NEUTRON BEAM DESIGN, P317