OUTPATIENT USE OF A PORTABLE INTERNATIONAL NORMALIZED RATIO/PROTHROMBIN TIME MONITOR

被引:16
作者
WHITE, RH [1 ]
BECKER, DM [1 ]
GUNTHERMAHER, MG [1 ]
机构
[1] UNIV VIRGINIA, DIV GEN MED, CHARLOTTESVILLE, VA USA
关键词
D O I
10.1097/00007611-199402000-00012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We review our collective experience over the past 4 years using a portable instrument that measures the International Normalized Ratio (INR) and the prothrombin time (PT). The device can be used readily in ambulatory clinic settings and by patients in their homes. The major advantage of the monitor is that the INR/PT can be measured quickly; if a change in the dose of warfarin is necessary, instructions can be discussed directly with the patient at the time of the visit. Compared with clinical laboratory determinations, monitor INRs are quite accurate, with approximately 85% of measurements within 0.9 INR units of the corresponding laboratory value. If necessary, monitor INRs can be adjusted to approximate a specific clinical laboratory's INRs with a regression formula derived from analysis of duplicate INRs using the monitor and the laboratory. Although the Food and Drug Administration has not yet approved use of the monitor by patients at home, use of a portable measuring device in the home by home health agencies may be valuable in selected cases.
引用
收藏
页码:206 / 210
页数:5
相关论文
共 24 条
[1]   EVALUATION OF A PORTABLE PROTHROMBIN TIME MONITOR FOR HOME-USE BY PATIENTS WHO REQUIRE LONG-TERM ORAL ANTICOAGULANT-THERAPY [J].
ANDERSON, DR ;
HARRISON, L ;
HIRSH, J .
ARCHIVES OF INTERNAL MEDICINE, 1993, 153 (12) :1441-1447
[2]   PATIENT SELF-MANAGEMENT OF ORAL ANTICOAGULATION GUIDED BY CAPILLARY (FINGERSTICK) WHOLE-BLOOD PROTHROMBIN TIMES [J].
ANSELL, J ;
HOLDEN, A ;
KNAPIC, N .
ARCHIVES OF INTERNAL MEDICINE, 1989, 149 (11) :2509-2511
[3]   COST-EFFECTIVENESS OF MONITORING WARFARIN THERAPY USING STANDARD VERSUS CAPILLARY PROTHROMBIN TIMES [J].
ANSELL, JE ;
HAMKE, AK ;
HOLDEN, A ;
KNAPIC, N .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1989, 91 (05) :587-589
[4]  
BECKER DM, 1993, ARCH PATHOL LAB MED, V117, P602
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   RELIANCE ON PROTHROMBIN TIME RATIOS CAUSES SIGNIFICANT ERRORS IN ANTICOAGULATION THERAPY [J].
BUSSEY, HI ;
FORCE, RW ;
BIANCO, TM ;
LEONARD, AD .
ARCHIVES OF INTERNAL MEDICINE, 1992, 152 (02) :278-282
[7]   MANAGEMENT OF ANTICOAGULATION IN OUTPATIENTS - EXPERIENCE WITH AN ANTICOAGULATION SERVICE IN A MUNICIPAL HOSPITAL SETTING [J].
DAVIS, FB ;
ESTRUCH, MT ;
SAMSONCORVERA, EB ;
VOIGT, GC ;
TOBIN, JD .
ARCHIVES OF INTERNAL MEDICINE, 1977, 137 (02) :197-202
[8]  
HIRSH J, 1991, NEW ENGL J MED, V324, P1865
[9]   ORAL ANTICOAGULANTS - MECHANISM OF ACTION, CLINICAL EFFECTIVENESS, AND OPTIMAL THERAPEUTIC RANGE [J].
HIRSH, J ;
DALEN, JE ;
DEYKIN, D ;
POLLER, L .
CHEST, 1992, 102 (04) :S312-S326
[10]  
HIRSH J, 1988, THROMB HAEMOSTASIS, V59, P129