PERFORMANCE OF A THERMAL IONIZATION MASS-SPECTROMETER WITH A DECELERATION LENS SYSTEM AND POST-DECELERATION DETECTOR SELECTION

被引:58
作者
VANCALSTEREN, P [1 ]
SCHWIETERS, JB [1 ]
机构
[1] FINNIGAN MAT GMBH,D-228197 BREMEN,GERMANY
来源
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES | 1995年 / 146卷
基金
英国自然环境研究理事会;
关键词
DECELERATION LENS SYSTEM; REPRODUCIBILITY; THERMAL IONIZATION MASS SPECTROMETRY;
D O I
10.1016/0168-1176(95)04208-3
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
An abundance sensitivity of < 10 ppb has been achieved with the redesigned retarding potential quadrupole (RPQ-II) on the Finnigan MAT 262 test instrument at the Finnigan MAT applications laboratory, and on the instrument installed at the Open University. The Open University instrument is equipped with a deflection unit after the RPQ-II to select a Faraday collector or a secondary electron multiplier (SEM) detector in addition to the standard MAT 262-RPQ-II configuration. The Faraday cup allows the evaluation of the transmission stability of the deceleration lens system independent of the effects introduced by the SEM, The yield of the RPQ-SEM has been determined with various methods and it is shown that the RPQ-II transmission error is small relative to the SEM conversion error. Using different calibration techniques, the long-term reproducibility on the Open University instrument for U-234/U-238 (NBS 0002) is < 0.7%, and for Th-230/Th-232 with an isotope ratio in the 6.1 x 10(-6) range is 1.3%. Measurement of the same Th standard with the instrument in the Finnigan application laboratory showed a reproducibility of 0.4% over a period of 1 week (10 samples). For both instruments, the achieved reproducibility is sufficient for the determination of the extreme isotope ratios required for U and Th disequilibrium studies.
引用
收藏
页码:119 / 129
页数:11
相关论文
共 10 条
[1]   U-TH-RA RADIOACTIVE DISEQUILIBRIA AND MAGMATIC PROCESSES [J].
CONDOMINES, M ;
HEMOND, C ;
ALLEGRE, CJ .
EARTH AND PLANETARY SCIENCE LETTERS, 1988, 90 (03) :243-262
[2]  
DAHL DA, 1988, SIMION USERS MANUAL
[3]  
Ewald H., 1953, METHODEN ANWENDUNGEN
[4]  
GARNER EL, 1971, NBS26027 SPEC PUB, P1
[5]  
HABFAST K, 1991, 1ST P A O NIER S IN, P75
[6]   1ST DETECTION OF FALLOUT CS-135 AND POTENTIAL APPLICATIONS OF CS-137/CS-135 RATIOS [J].
LEE, T ;
KU, TL ;
LU, HL ;
CHEN, JC .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1993, 57 (14) :3493-3497
[7]   MEASUREMENT OF TH-230/TH-232 RATIOS IN YOUNG VOLCANIC-ROCKS BY SINGLE-SECTOR THERMAL IONIZATION MASS-SPECTROMETRY [J].
MCDERMOTT, F ;
ELLIOTT, TR ;
VANCALSTEREN, P ;
HAWKESWORTH, CJ .
CHEMICAL GEOLOGY, 1993, 103 (1-4) :283-292
[9]  
WILLIAMS RW, 1989, GEOCHIM COSMOCHIM AC, V53, P1607
[10]   GIOS-BEAMTRACE - A PROGRAM PACKAGE TO DETERMINE OPTICAL-PROPERTIES OF INTENSE ION-BEAMS [J].
WOLLNIK, H ;
BREZINA, J ;
BERZ, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 258 (03) :408-411