ARTERIAL, CAPILLARY, AND VENOUS TRANSIT TIMES AND DISPERSION MEASURED IN ISOLATED RABBIT LUNGS

被引:11
作者
AYAPPA, I [1 ]
BROWN, LV [1 ]
WANG, PM [1 ]
LAIFOOK, SJ [1 ]
机构
[1] UNIV KENTUCKY,CTR BIOMED ENGN,WENNER GREN RES LAB,LEXINGTON,KY 40506
关键词
FLUORESCENCE VIDEOMICROSCOPY; PULMONARY MICROCIRCULATION; GAS EXCHANGE;
D O I
10.1152/jappl.1995.79.1.261
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Transit time and relative dispersion of the arterial, capillary, and venous segments of the pulmonary circulation were measured in isolated perfused rabbit lungs. Fluorescence videomicroscopy was used to record the passage of dye through the main pulmonary artery, subpleural microcirculation, and venous outflow. Dye dilution curves were obtained at the main pulmonary artery, subpleural arterioles and venules, and pulmonary vein. Measurements were made at 5-cmH(2)O airway pressure, at blood flows of similar to 80, 50, and 25 ml . min(-1) . kg(-1), and at left atrial pressures of similar to 0 cmH(2)O (zone 2) and similar to 12 cmH(2)O (zone 3). The dye dilution curves were modeled as lagged normal density curves that were used to calculate transit time and relative dispersion between the pulmonary artery and arteriole (artery), arteriole and venule (capillary), venule and pulmonary vein (vein), and pulmonary artery and pulmonary vein (whole lung). In open-chest anesthetized dogs, the passage of dye was recorded from the subpleural arterioles and venules between the seventh and eighth ribs in the left lateral position. At comparable blood flows, capillary transit time was larger in the dog than in the rabbit lung [3.4 +/- 2.4 (SD) vs, 0.87 +/- 0.47 s]. In the rabbit lung, relative dispersion was greater in pulmonary capillaries (average values 0.83-1.6) and veins (0.91-1.6) than in arteries (0.39-0.50), which was similar to the whole lung dispersion (0.47-0.52). A similarly high dispersion (0.93) was measured in the dog's pulmonary capillaries. Thus high dispersion in pulmonary capillaries and veins cannot be detected by whole lung dispersion measurements.
引用
收藏
页码:261 / 269
页数:9
相关论文
共 33 条
[1]  
BASSINGTHWAIGHT.JB, 1966, CIRC RES, V18, P398
[2]  
BASSINGTHWAIGHT.JB, 1967, J APPL PHYSIOL, V22, P879
[3]  
BASSINGTHWAIGHT.JB, 1966, CIRC RES, V19, P332
[4]  
BOCK J C, 1990, Biomedical Instrumentation and Technology, V24, P42
[5]   MODEL-FREE DECONVOLUTION TECHNIQUES FOR ESTIMATING VASCULAR TRANSPORT FUNCTIONS [J].
BRONIKOWSKI, TA ;
DAWSON, CA ;
LINEHAN, JH .
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1983, 14 (05) :411-429
[6]   DISTRIBUTION OF PULMONARY CAPILLARY TRANSIT TIMES IN RECRUITED NETWORKS [J].
CAPEN, RL ;
HANSON, WL ;
LATHAM, LP ;
DAWSON, CA ;
WAGNER, WW .
JOURNAL OF APPLIED PHYSIOLOGY, 1990, 69 (02) :473-478
[7]   COMPARISON OF DIRECT AND INDIRECT MEASUREMENTS OF PULMONARY CAPILLARY TRANSIT TIMES [J].
CAPEN, RL ;
LATHAM, LP ;
WAGNER, WW .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 62 (03) :1150-1154
[8]   INTRA-PULMONARY BLOOD-FLOW REDISTRIBUTION DURING HYPOXIA INCREASES GAS-EXCHANGE SURFACE-AREA [J].
CAPEN, RL ;
WAGNER, WW .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 52 (06) :1575-1580
[9]   MODEL-FREE NUMERICAL DECONVOLUTION OF RECIRCULATING INDICATOR CONCENTRATION CURVES [J].
CLOUGH, AV ;
CUI, DY ;
LINEHAN, JH ;
KRENZ, GS ;
DAWSON, CA ;
MARON, MB .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (03) :1444-1453
[10]  
Coulam C M, 1967, Comput Biomed Res, V1, P124, DOI 10.1016/0010-4809(67)90011-0