SINGLE X-RAY ABSORPTIOMETRY - PERFORMANCE-CHARACTERISTICS AND COMPARISON WITH SINGLE-PHOTON ABSORPTIOMETRY

被引:31
作者
BORG, J
MOLLGAARD, A
RIIS, BJ
机构
[1] CTR CLIN & BASIC RES,DK-2750 BALLERUP,DENMARK
[2] OSTEOMETER AS,RODOVRE,DENMARK
关键词
FOREARM SCANNING; PERIPHERAL BONE MASS; SINGLE X-RAY ABSORPTIOMETRY;
D O I
10.1007/BF01622260
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of the present study was to evaluate a new device for measurement of forearm bone mass using the technique of single X-ray absorptiometry (SXA, DTX-100; Osteometer A/S, Rodovre, Denmark), and to compare the performance with the more traditional single photon absorptiometry (SPA, DT 100; Osteometer A/S, Rodovre, Denmark). The SPA phantom measurements showed a coefficient of variation of 0.43% and 0.42% for bone mineral content (BMC) and bone mineral density (BMD), respectively (39 months including seven source changes). The SXA precision errors were slightly lower with values of 0.30% and 0.30%, respectively. The patient measurements showed SPA coefficients of variation of 0.85% and 0.99% (BMC and BMD) and SXA coefficients of variation of 0.56% and 0.83%, respectively. The correlation between SPA and SXA values performed in 377 individuals yielded r values of 0.99 an 0.98 for BMC and BMD, respectively. The correlations between SX4 measurements of the dominant and non-dominant forearm yielded an r-value of 0.95, with a slope of 0.949 (p <0.001) and an intercept of 0.204 (p <0.05). The nondominant forearm thus had approximately 3% lower BMC than the dominant (the same was true for BMD). Correlations to spine and femur ranged from r = 0.48 to r = 0.75. In conclusion, the new single X-ray absorptiometry forearm bone densitometer described in this paper has performance characteristics which allows it to be used both for diagnostic purposes and for the followup of treatment.
引用
收藏
页码:377 / 381
页数:5
相关论文
共 26 条
[1]  
BLACK DM, 1992, J BONE MINER RES, V7, P633
[2]  
CAMERON JR, 1963, SCIENCE, V142, P230
[3]   LONG-TERM REPRODUCIBILITY OF BONE-MINERAL CONTENT MEASUREMENTS [J].
CHRISTIANSEN, C ;
RODBRO, P .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1977, 37 (04) :321-323
[4]   DENSITOMETRY OF THE RADIUS USING SINGLE AND DUAL-ENERGY ABSORPTIOMETRY [J].
FAULKNER, KG ;
MCCLUNG, MR ;
SCHMEER, MS ;
ROBERTS, LA ;
GAITHER, KW .
CALCIFIED TISSUE INTERNATIONAL, 1994, 54 (03) :208-211
[5]   PREDICTING VARIOUS FRAGILITY FRACTURES IN WOMEN BY FOREARM BONE DENSITOMETRY - A FOLLOW-UP-STUDY [J].
GARDSELL, P ;
JOHNELL, O ;
NILSSON, BE ;
GULLBERG, B .
CALCIFIED TISSUE INTERNATIONAL, 1993, 52 (05) :348-353
[6]   TOTAL-BODY BONE-MINERAL INVIVO BY DUAL PHOTON-ABSORPTIOMETRY .1. MEASUREMENT PROCEDURES [J].
GOTFREDSEN, A ;
BORG, J ;
CHRISTIANSEN, C ;
MAZESS, RB .
CLINICAL PHYSIOLOGY, 1984, 4 (04) :343-355
[7]  
HANSEN MA, 1990, J NUCL MED, V31, P1156
[8]  
HANSEN MA, 1990, SCAND J CLIN LAB INV, V5, P517
[9]   MEASUREMENT OF THE SUBCUTANEOUS FAT IN THE DISTAL FOREARM BY SINGLE PHOTON-ABSORPTIOMETRY [J].
HASSAGER, C ;
BORG, J ;
CHRISTIANSEN, C .
METABOLISM-CLINICAL AND EXPERIMENTAL, 1989, 38 (02) :159-165
[10]  
HASSAGER C, 1991, OSTEOPOROSIS INT, V1, P1250