CARDIAC-OUTPUT DURING EXERCISE MEASURED BY ACETYLENE REBREATHING, THERMODILUTION, AND FICK TECHNIQUES

被引:37
作者
HSIA, CCW
HERAZO, LF
RAMANATHAN, M
JOHNSON, RL
机构
[1] Div. of Pulmonary Research, Dept. of Medicine, Univ. of Texas SW Medical Center, Dallas, TX 75235-9034
关键词
PULMONARY BLOOD FLOW; MIXING EFFICIENCY; TEMPERATURE CORRECTION; HEMATOCRIT CORRECTION; ACETYLENE; DOG;
D O I
10.1152/jappl.1995.78.4.1612
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
In dogs during exercise, respiratory rate can reach 200 breaths/min, blood temperature can exceed 42 degrees C, and hematocrit can approach 60%. To determine whether these changes significantly affect the measurement of cardiac output by the acetylene rebreathing method (Q(CRB)), we compared estimates of Q(CRB) With those measured by thermodilution and Fick (Q(CFI)) techniques in nine dogs at rest and during steady-state exercise on a treadmill up to near-maximal workloads. Solubility of acetylene in blood was corrected to the simultaneously measured blood temperature and hematocrit. Results were also adjusted for mixing efficiency. Up to a Q(CFI) Of 20 l/min, Q(CRB) was not significantly different from Q(CFI) (P > 0.05) However, cardiac output measured by thermodilution was consistently higher than those measured by the other techniques (P < 0.0001). We conclude that the overall agreement between Q(CRB) and Q(CFI) estimates supports the validity of the rebreathing technique under exercise conditions where body temperature and hematocrit are changing rapidly and the breathing pattern is unrestrained. Systematic error by the thermodilution technique may be related to a variety of methodological issues as well as possible dissipation of cooling into the myocardial tissue and subsequent incomplete washout.
引用
收藏
页码:1612 / 1616
页数:5
相关论文
共 24 条
[1]   A MOUTHPIECE FACE MASK FOR THE EXERCISING DOG [J].
AMPIL, J ;
CARLIN, JI ;
JOHNSON, RL .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (05) :2240-2244
[2]   ERRORS IN THERMODILUTION CARDIAC-OUTPUT MEASUREMENTS CAUSED BY RAPID PULMONARY-ARTERY TEMPERATURE DECREASES AFTER CARDIOPULMONARY BYPASS [J].
BAZARAL, MG ;
PETRE, J ;
NOVOA, R .
ANESTHESIOLOGY, 1992, 77 (01) :31-37
[3]   INVITRO DETERMINATION OF ACCURACY OF CARDIAC-OUTPUT MEASUREMENTS BY THERMAL DILUTION [J].
BILFINGER, TV ;
LIN, CY ;
ANAGNOSTOPOULOS, CE .
JOURNAL OF SURGICAL RESEARCH, 1982, 33 (05) :409-414
[4]   MEASUREMENT OF CARDIAC OUTPUT BY THERMAL DILUTION IN MAN [J].
BRANTHWAITE, MA ;
BRADLEY, RD .
JOURNAL OF APPLIED PHYSIOLOGY, 1968, 24 (03) :434-+
[5]   RECRUITMENT OF LUNG DIFFUSING-CAPACITY WITH EXERCISE BEFORE AND AFTER PNEUMONECTOMY IN DOGS [J].
CARLIN, JI ;
HSIA, CCW ;
CASSIDY, SS ;
RAMANATHAN, M ;
CLIFFORD, PS ;
JOHNSON, RL .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (01) :135-142
[6]   NONINVASIVE DIFFUSING-CAPACITY AND CARDIAC-OUTPUT IN EXERCISING DOGS [J].
CARLIN, JI ;
CASSIDY, SS ;
RAJAGOPAL, U ;
CLIFFORD, PS ;
JOHNSON, RL .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 65 (02) :669-674
[7]   EVALUATION OF LUNG DIFFUSING-CAPACITY BY PHYSIOLOGICAL AND MORPHOMETRIC TECHNIQUES [J].
CRAPO, JD ;
CRAPO, RO ;
JENSEN, RL ;
MERCER, RR ;
WEIBEL, ER .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (05) :2083-2091
[8]   INACCURACY OF CARDIAC-OUTPUT BY THERMODILUTION DURING ACUTE TRICUSPID REGURGITATION [J].
HEERDT, PM ;
POND, CG ;
BLESSIOS, GA ;
ROSENBLOOM, M .
ANNALS OF THORACIC SURGERY, 1992, 53 (04) :706-708
[9]   PULMONARY BLOOD-FLOW, DIFFUSING-CAPACITY AND TISSUE VOLUME BY RE-BREATHING - THEORY [J].
HOOK, C ;
MEYER, M .
RESPIRATION PHYSIOLOGY, 1982, 48 (02) :255-279
[10]   THERMAL-DILUTION TECHNICS [J].
HOSIE, KF .
CIRCULATION RESEARCH, 1962, 10 (03) :491-&