DETERMINATION OF INORGANIC SULFIDE AND CYANIDE IN BLOOD USING SPECIFIC ION ELECTRODES - APPLICATION TO THE INVESTIGATION OF HYDROGEN-SULFIDE AND CYANIDE POISONING

被引:42
作者
MCANALLEY, BH
LOWRY, WT
OLIVER, RD
GARRIOTT, JC
机构
[1] Southwestern Institute of Forensic Sciences, Dallas, TX
关键词
D O I
10.1093/jat/3.3.111
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe a method for the quantitative determination of cyanide and sulfide ions using specific ion electrodes in combination with Conway microdiffuslon cells. The response of two types of electrodes to both Ions In standard solutions is presented. The method Is applicable to measurement of low to toxic concentrations of both ions in biologic specimens. Five autopsy cases with history of sudden death from noxious gases were studied using this technique, and high concentrations of sulfide ion (1.70-3.75 mg/L) were found In the blood samples. © 1979 Oxford University Press.
引用
收藏
页码:111 / 114
页数:4
相关论文
共 13 条
[1]  
ALBAUM HG, 1946, J BIOL CHEM, V163, P641
[2]   INVITRO PRODUCTION OF CYANIDE IN NORMAL HUMAN-BLOOD AND INFLUENCE OF THIOCYANATE AND STORAGE TEMPERATURE [J].
BALLANTYNE, B .
CLINICAL TOXICOLOGY, 1977, 11 (02) :173-193
[3]   NITRITE AND THIOSULFATE THERAPY IN CYANIDE POISONING [J].
CHEN, KK ;
ROSE, CL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1952, 149 (02) :113-119
[4]   TOXICITY OF HYDROGEN SULPHIDE AND OTHER SULPHIDES [J].
EVANS, CL .
QUARTERLY JOURNAL OF EXPERIMENTAL PHYSIOLOGY AND COGNATE MEDICAL SCIENCES, 1967, 52 (03) :231-&
[5]   ELECTRODE INDICATOR TECHNIQUE FOR MEASURING LOW-LEVELS OF CYANIDE [J].
FRANT, MS ;
ROSS, JW ;
RISEMAN, JH .
ANALYTICAL CHEMISTRY, 1972, 44 (13) :2227-&
[6]  
GERAIS P, 1963, REV PRACT, V13, P1313
[7]  
Rehling C J, 1967, Prog Chem Toxicol, V3, P363
[8]  
Riseman J. H., 1972, American Laboratory, V4, P63
[9]  
SCHELER W, 1963, ACTA BIOL MED GER, V11, P194
[10]  
SHANAHAN R, 1973, Journal of Forensic Sciences, V18, P25