COULOMBIC EFFICIENCY OF LEAD-ACID-BATTERIES, PARTICULARLY IN REMOTE-AREA POWER-SUPPLY (RAPS) SYSTEMS

被引:12
作者
KAUSHIK, R [1 ]
MAWSTON, IG [1 ]
机构
[1] YUASA JRA BATTERIES LTD,POB 13-343,ONEHUNGA,AUCKLAND,NEW ZEALAND
关键词
D O I
10.1016/0378-7753(91)80055-3
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper investigates the effect of charging regimes and battery designs - and the combined effects of the two parameters - on the overall coulombic efficiency of lead/acid batteries operating in RAPS systems. Under such service, it is highly desirable to achieve a good match between the energy source and the battery characteristics in order to achieve optimum coulombic efficiency at a given state-of-charge of the battery.
引用
收藏
页码:377 / 383
页数:7
相关论文
共 6 条
[1]  
GIBSON IK, 1980, POWER SOURCES, V8, P365
[2]   DISCHARGE CHARACTERIZATION OF LEAD-ACID-BATTERIES [J].
KAUSHIK, R ;
MAWSTON, IG .
JOURNAL OF POWER SOURCES, 1989, 28 (1-2) :161-169
[3]  
MCNICOL BD, 1984, POWER SOURCES ELECTR, P429
[4]  
SMITH G, 1964, STORAGE BATTERIES
[5]  
WILLIHNGANZ E, 1975, POWER SOURCES, V5, P45
[6]  
YUASA JRA, UNPUB U AUCKLAND JOI