ASSESSMENT OF CHROMATOGRAPHIC PEAK PURITY OF DRUGS BY MULTIVARIATE-ANALYSIS OF DIODE-ARRAY AND MASS-SPECTROMETRIC DATA

被引:22
作者
LINCOLN, D
FELL, AF
ANDERSON, NH
ENGLAND, D
机构
[1] UNIV BRADFORD,SCH PHARM,BRADFORD BD7 1DP,W YORKSHIRE,ENGLAND
[2] STERLING WINTHROP RES CTR,ALNWICK NE66 2JH,ENGLAND
关键词
LIQUID CHROMATOGRAPHY; THERMOSPRAY MASS SPECTROMETRY; PEAK PURITY; MULTIVARIATE ANALYSIS; PRINCIPAL COMPONENT ANALYSIS; DIODE-ARRAY DETECTION;
D O I
10.1016/0731-7085(91)80089-R
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Numerous multivariate chemometric approaches have been developed for LC-UV data acquired using a diode-array detector (DAD), but these methods have not been widely exploited for LC-MS data. Principal component analysis (PCA) and subsequent axis rotation within the reduced factor space are assessed for LC-DAD and LC-MS data as approaches for estimating the number of components (i.e. the rank of the data) under a single chromatographic peak for compounds whose UV-spectra are very similar. Multivariate techniques for LC-DAD data are shown to suffer from inherent limitations of sensitivity for the minor components. The novel technique in LC-MS of plotting the rotated PCA data in two-dimensional factor space generates characteristic ion clusters, giving a visual criterion of peak purity. Single ion chromatograms produced subsequently confirm the profile of each coeluting component and give evidence of the degree of peak overlap. The application of this new chemometric technique to the detection of low levels of coeluting impurities by LC-MS is discussed as a novel approach for the validation of LC separations in pharmaceutical research and development.
引用
收藏
页码:837 / 844
页数:8
相关论文
共 20 条
[1]  
ALFREDSON T, 1985, AM LAB, V17, P40
[2]   RAPID-SCANNING, MULTI-CHANNEL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETECTION OF ZIMELDINE AND METABOLITES WITH 3-DIMENSIONAL GRAPHICS AND CONTOUR PLOTTING [J].
CLARK, BJ ;
FELL, AF ;
SCOTT, HP ;
WESTERLUND, D .
JOURNAL OF CHROMATOGRAPHY, 1984, 286 (MAR) :261-273
[3]  
DASTLEDINE JB, 1992, J CHROMATOGR, V592, P27
[4]   UNIVERSAL, MULTI-CHANNEL ULTRAVIOLET DETECTION IN THE PURITY ANALYSIS OF 2-ETHYL-3-(4-HYDROXYBENZOYL)INDOLIZINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DRENTH, BFH ;
GHIJSEN, RT ;
DEZEEUW, RA .
JOURNAL OF CHROMATOGRAPHY, 1982, 238 (01) :113-120
[5]   DUAL-WAVELENGTH ABSORBANCE RATIO FOR SOLUTE RECOGNITION IN LIQUID-CHROMATOGRAPHY [J].
DROUEN, ACJH ;
BILLIET, HAH ;
DEGALAN, L .
ANALYTICAL CHEMISTRY, 1984, 56 (06) :971-978
[6]   COMPUTER-AIDED MULTICHANNEL DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
FELL, AF ;
SCOTT, HP ;
GILL, R ;
MOFFAT, AC .
CHROMATOGRAPHIA, 1982, 16 :69-78
[7]   APPLICATIONS OF RAPID-SCANNING MULTICHANNEL DETECTORS IN CHROMATOGRAPHY - PLENARY LECTURE [J].
FELL, AF ;
SCOTT, HP ;
GILL, R ;
MOFFAT, AC .
JOURNAL OF CHROMATOGRAPHY, 1983, 273 (01) :3-17
[8]   PEAK PURITY CONTROL IN LIQUID-CHROMATOGRAPHY WITH PHOTODIODE-ARRAY DETECTION BY A FIXED SIZE MOVING WINDOW EVOLVING FACTOR-ANALYSIS [J].
KELLER, HR ;
MASSART, DL .
ANALYTICA CHIMICA ACTA, 1991, 246 (02) :379-390
[9]   HEURISTIC EVOLVING LATENT PROJECTIONS - RESOLVING 2-WAY MULTICOMPONENT DATA .1. SELECTIVITY, LATENT-PROJECTIVE GRAPH, DATASCOPE, LOCAL RANK, AND UNIQUE RESOLUTION [J].
KVALHEIM, OM ;
LIANG, YZ .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :936-946
[10]   EVOLVING FACTOR-ANALYSIS FOR THE RESOLUTION OF OVERLAPPING CHROMATOGRAPHIC PEAKS [J].
MAEDER, M .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :527-530