PERFORMANCE OF A VOLUME H- ION-SOURCE WITH A TOROIDAL DISCHARGE CHAMBER

被引:6
作者
PRELEC, K
ALESSI, JG
机构
关键词
D O I
10.1063/1.1141257
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new volume H- ion source with a toroidal discharge chamber has been designed. Its main feature is a full rotational symmetry, including a conically shaped dipole field separating the main toroidal discharge from the central extraction chamber. Measurements of the H- yield and the accompanying electron component have been performed, both for this rotationally symmetric geometry and for a standard line dipole geometry. With the rotationally symmetric geometry, the H- yield was up to 30 mA through an aperture of 1 cm2, while the ratio Ie /I H- depended greatly on the value of I H- and was about 20-30 for the highest currents. The beam emittance was measured for the rotationally symmetric geometry, and was found to be εn (90%)≊0.094 π cm mrad for a 21-mA beam. An estimate of the H- ion temperature from the measured emittance gives a value of approximately 3.6 eV.
引用
收藏
页码:415 / 417
页数:3
相关论文
共 6 条
[1]  
ALLISON PA, 1987, AIP C P, V158, P465
[2]  
PRELEC K, 1988, 3RD P EUR WORKSH PRO
[3]  
PRELEC K, 1988, JUN P EUR PART ACC C
[4]  
PRELEC K, 1986, 2ND P EUR WORKSH PRO
[5]  
PRELEC K, 1989, 1989 P PART ACC C CH
[6]  
STEVENS RR, 1987, AIP C P, V158, P271