DOUBLE-ECHO MULTISLICE PROTON SPECTROSCOPIC IMAGING USING HADAMARD SLICE ENCODING

被引:18
作者
DREHER, W
LEIBFRITZ, D
机构
[1] Universität Bremen, Bremen
关键词
SPECTROSCOPIC IMAGING; MULTISLICE; HADAMARD ENCODING; RAT BRAIN;
D O I
10.1002/mrm.1910310604
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Simultaneous multislice proton spectroscopic imaging (SI) is presented using a pulse sequence with multifrequency selective RF excitation and Hadamard encoding in the slice direction, and conventional Fourier phase encoding in the in-plane directions. Double-echo data acquisition is used to increase the spectral information of the experiment. Tests on a phantom demonstrate the quality of the slice selection. Results of in vivo measurements on the healthy rat brain show that spectra with a high signal-to-noise ratio can be acquired from four slices within 32 min. The measurements were performed at 4.7 T using a field of view of 32 x 32 mm(2), a slice thickness of 3 mm, and a voxel size of 12 mu l. The proposed method is a useful alternative to sequential multislice SI and 3D SI. Furthermore, it is possible to combine sequential and simultaneous multislice SI.
引用
收藏
页码:596 / 600
页数:5
相关论文
共 16 条