ACCURACY AND INTEROBSERVER RELIABILITY OF SCALP ICTAL EEG

被引:85
作者
WALCZAK, TS
RADTKE, RA
LEWIS, DV
机构
[1] DUKE UNIV,MED CTR,DEPT MED NEUROL,DURHAM,NC 27710
[2] DUKE UNIV,MED CTR,DEPT PEDIAT NEUROL,DURHAM,NC 27710
关键词
D O I
10.1212/WNL.42.12.2279
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We studied the accuracy and reliability of scalp ictal EEG in 137 complex partial seizures (119 temporal and 18 extratemporal) in 35 patients in whom we knew the correct site of seizure origin because all patients had been seizure-free for more than 2 years after seizure surgery. Three electroencephalographers independently determined side of seizure origin based on activity at onset of electrographic seizure (ASO), rhythmic theta and alpha (RTA), postictal findings (PIF), and the electrographic seizure as a whole. When all seizures were analyzed, including those with generalized features or obscured by artifact, we determined side of seizure onset correctly in 76% to 83% of temporal seizures and 47% to 65% of extratemporal seizures. In most of the remainder, a lateralization judgment was impossible. When analysis was confined to those seizures in which lateralization was possible, we correctly lateralized 93% to 99% of temporal seizures and 89% to 100% of extratemporal seizures. Interobserver reliability was excellent. RTA and PIF were more accurate than ASO. RTA was significantly more common in temporal seizures. Our data indicate that lateralization by scalp EEG is highly accurate and reliable.
引用
收藏
页码:2279 / 2285
页数:7
相关论文
共 18 条
[1]  
AJMONEMARSAN C, 1957, EPILEPTIC SEIZURE IT, P175
[2]  
BLUME WT, 1984, ELECTROEN CLIN NEURO, V57, P295, DOI 10.1016/0013-4694(84)90151-2
[3]   TEMPORAL LOBECTOMY AND INDEPENDENT BITEMPORAL INTERICTAL ACTIVITY - WHAT DEGREE OF LATERALIZATION IS SUFFICIENT [J].
CHUNG, MY ;
WALCZAK, TS ;
LEWIS, DV ;
DAWSON, DV ;
RADTKE, R .
EPILEPSIA, 1991, 32 (02) :195-201
[4]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[5]  
ENGEL J, 1980, ELECTROEN CLIN NEURO, V50, pP160
[6]  
Fleiss JL, 2003, STAT METHODS RATES P, P598
[7]  
Gastaut H., 1953, EPILEPSIA BOSTON, V2, P59, DOI [10.1111/j.1528-1157.1953.tb03310.x, DOI 10.1111/J.1528-1157.1953.TB03310.X]
[8]  
Gibbs FA., 1952, ATLAS ELECTROENCEPHA, VII
[9]   THE POSTICTAL ELECTROENCEPHALOGRAM [J].
KAIBARA, M ;
BLUME, WT .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1988, 70 (02) :99-104
[10]   RELIABILITY OF CLINICAL METHODS, DATA AND JUDGMENTS .2. [J].
KORAN, LM .
NEW ENGLAND JOURNAL OF MEDICINE, 1975, 293 (14) :695-701