DETERMINATION OF OBJECT CONTOUR FROM PROJECTIONS FOR ATTENUATION CORRECTION IN CRANIAL POSITRON EMISSION TOMOGRAPHY

被引:197
作者
BERGSTROM, M
LITTON, J
ERIKSSON, L
BOHM, C
BLOMQVIST, G
机构
[1] KAROLINSKA HOSP, DEPT NEURORADIOL, S-10401 STOCKHOLM, SWEDEN
[2] KAROLINSKA INST, KARLINSKA HOSP, DEPT CLIN NEUROPHYSIOL, S-10401 STOCKHOLM 60, SWEDEN
[3] KAROLINSKA INST, KARLINSKA HOSP, DEPT RADIAT PHYS, S-10401 STOCKHOLM 60, SWEDEN
[4] UNIV STOCKHOLM, DEPT PHYS, S-10691 STOCKHOLM, SWEDEN
关键词
D O I
10.1097/00004728-198204000-00022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A contour-finding algorithm is described by which the object periphery is outlined in positron emission tomography (PET) scans. The positions of maximum slopes are determined in the projections. These positions correspond well to the borders of the activity region. By backprojecting these points in the projections into the image plane, the size and shape of the region of activity may be outlined. Cord lengths across this region are then determined for attenuation correction. The accuracy of the algorithm was tested on 10 patients with both PET and computed tomography (CT) examinations. Points on the periphery of the skull, as determined with the contour-finding algorithm in PET, coincided with those determined by CT, with a standard deviation of 1.5 mm and a maximum deviation of 3.5 mm. In testing the influence of the skull bone on the PET values, it was found that ignoring the higher attenuation coefficient of bone, 5 mm thick, in the attenuation correction caused an error in the determination of activity of 11% peripherally and 6% centrally in the object. These errors could be reduced to less than 1% by increasing the assumed attenuating region by 4.5 mm.
引用
收藏
页码:365 / 372
页数:8
相关论文
共 22 条
  • [1] HEAD FIXATION DEVICE FOR REPRODUCIBLE POSITION ALIGNMENT IN TRANSMISSION CT AND POSITRON EMISSION TOMOGRAPHY
    BERGSTROM, M
    BOETHIUS, J
    ERIKSSON, L
    GREITZ, T
    RIBBE, T
    WIDEN, L
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1981, 5 (01) : 136 - 141
  • [2] CORRECTIONS FOR ATTENUATION, SCATTERED RADIATION, AND RANDOM COINCIDENCES IN A RING DETECTOR POSITRON EMISSION TRANSAXIAL TOMOGRAPH
    BERGSTROM, M
    BOHM, C
    ERICSON, K
    ERIKSSON, L
    LITTON, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1980, 27 (01) : 549 - 554
  • [3] COMPUTER-ASSISTED RING-DECTOR POSITRON CAMERA SYSTEM FOR RECONSTRUCTION TOMOGRAPHY OF BRAIN
    BOHM, C
    ERIKSSON, L
    BERGSTROM, M
    LITTON, J
    SUNDMAN, R
    SINGH, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 624 - 637
  • [4] CHO ZH, 1977, RECONSTRUCTION TOMOG, P393
  • [5] DERENZO SE, 1975, J NUCL MED, V16, P1166
  • [6] IMAGING PROPERTIES OF A POSITRON TOMOGRAPH WITH 280-BGO-CRYSTALS
    DERENZO, SE
    BUDINGER, TF
    HUESMAN, RH
    CAHOON, JL
    VULETICH, T
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) : 81 - 89
  • [7] POSITRON EMISSION TOMOGRAPHY IN THE EVALUATION OF SUBDURAL HEMATOMAS
    ERICSON, K
    BERGSTROM, M
    ERIKSSON, L
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (06) : 737 - 745
  • [8] ONE YEAR EXPERIENCE WITH A HIGH-RESOLUTION RING DETECTOR POSITRON CAMERA SYSTEM - PRESENT STATUS AND FUTURE-PLANS
    ERIKSSON, L
    BOHM, C
    GREITZ, T
    LITTON, J
    WIDEN, L
    BERGSTROM, M
    ERICSON, K
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1980, 27 (01) : 435 - 444
  • [9] RING DETECTOR POSITRON CAMERA SYSTEM - ITS MERITS - CLINICAL EXPERIENCE
    ERIKSSON, L
    BERGSTROM, M
    BOHM, C
    GREITZ, T
    LITTON, J
    SUNDMAN, R
    WIDEN, L
    [J]. NEURORADIOLOGY, 1978, 16 : 572 - 574
  • [10] ERIKSSON L, 1980, USIP8004 U STOCKH RE