PARTICLE RETENTION IN AIRWAYS ESTIMATED BY UNBIASED STEREOLOGY AND PHOTOMETRY

被引:11
作者
GEISER, M
CRUZORIVE, LM
WABER, U
HOF, VI
GEHR, P
机构
[1] Institute of Anatomy, Division of Histology, University of Bern
[2] Stereology Unit, University of Bern
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 1995年 / 8卷 / 02期
关键词
AEROSOL; AIRWAY; DEPOSITION; FRACTIONATOR; HAMSTER; PHOTOMETRY; RETENTION; STEREOLOGY;
D O I
10.1089/jam.1995.8.149
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The retention pattern of 6 mu m polystyrene particles at two breathing modes was studied by unbiased stereology in hamster airways (trachea, main bronchi and intrapulmonary conducting airways) and in the inhalation cannula. In addition, the total particle number estimated by stereology was compared with total deposition by laser photometry. Seven Syrian Golden hamsters which were artificially ventilated with continuous-negative-pressure ventilation inhaled the aerosol through an intratracheal cannula. Four of them were ventilated with a tidal volume V-t = 1.0 ml and a breathing frequency f of 60 min(-1) (group A), three of them with V-t = 0.5 ml and the same f (group B). Immediately after inhalation, the lungs of all animals were fixed by intravascular perfusion, sampled and processed for stereologic fractionator analysis on light microscopic sections. The inhalation cannula was rinsed and particles counted in a hemocytometer. The total particle numbers by stereology were not found to be significantly different from total deposition data by laser photometry in group A (V-t = 1.0 ml) animals, whereas they were different (lower) in group B animals. Differences in the patterns of particle retention were observed and biologic differences were apparent, although not statistically significant. In the short time of 20 minutes from the beginning of the inhalation to the beginning of fixation, a significant, but variable number of particles was found phagocytized by airway macrophages, indicating the importance of airway macrophages in particle clearance. This study shows the application and the limitation of hitherto conventional systematic sampling for particle distribution analyses in conducting airways of small rodents and of photometric measurements.
引用
收藏
页码:149 / 165
页数:17
相关论文
共 26 条
[1]  
BRAIN J.D., VALBERG P.A., Deposition of aerosol in the respiratory tract, Am. Rev. Respir.Dis., 120, pp. 1325-1373, (1979)
[2]  
CHAN H.K., Use of single photon eirdssion computed tomography in aerosol studies, J. Aerosol Med., 6, pp. 23-36, (1993)
[3]  
CHATFIELD C., COLLINS A.J., Introduction to Multivariate Analysis, (1980)
[4]  
CRUZ-ORIVE L.M., On the empirical variance of a fractionator estimate, J. Microsc., 160, pp. 89-95, (1990)
[5]  
GEISER M., CRUZ-ORIVE L.M., IMHOF V., GEHR P., Assessment of particle retention and clearance in the intrapulmonary conducting airways of hamster lungs with the fractionator, J. Microsc., 160, pp. 75-88, (1990)
[6]  
GEISER M., IMHOF V., GEHR P., CRUZ-ORIVE L.M., Histological and stereological analysis of particle retention in the conducting airways of hamster lungs, J. Aerosol Med., 3, pp. 131-145, (1990)
[7]  
GEISER M., BAUMANN M., CRUZ-ORIVE L.M., IMHOF V., WABER U., GEHR P., The effect of particle inhalation on macrophage number and phagocytic activity in the intrapulmonary conducting airways of hamsters, Am, J. Respir. Cell Mol. Biol., 10, pp. 594-603, (1994)
[8]  
GUNDERSEN H.J.G., Notes on the estimation of the numerical density of aibitrary profiles: the edge effect, J. Microsc. Ill, pp. 219-223, (1977)
[9]  
GUNDERSEN H.J.G., Stereology of arbitrary particles, A review of unbiased number and size estimators and the presentation of some new ones, in memory of William R. Thompson. J. Microsc., 143, pp. 3-45, (1986)
[10]  
GUNDERSEN H.J.G., OSTERBY R., Optimizing sampling efficiency of stereological studies in biology: or ‘Do more less well!’ J. Microsc., 121, pp. 65-73, (1981)