SIZE EXCLUSION CHROMATOGRAPHY CALIBRATION ASSESSMENT UTILIZING COUPLED MOLECULAR-WEIGHT DETECTORS

被引:28
作者
MOUREY, TH [1 ]
MILLER, SM [1 ]
BALKE, ST [1 ]
机构
[1] UNIV TORONTO,DEPT CHEM ENGN & APPL CHEM,TORONTO M5S 1A4,ONTARIO,CANADA
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1990年 / 13卷 / 03期
关键词
D O I
10.1080/01483919008051797
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper shows that the usual method of representing an SEC calibration curve by a single polynomial curve may often be inadequate with new high resolution columns. Data points wind about the fitted line. The significant magnitude and systematic nature of these deviations clearly appear when a plot of residuals is derived from the conventional calibration curve and expressed in terms of the percent error in molecular weight. The deviation of the calibration data from the fitted line was approximately 10% for the conventional molecular weight and intrinsic viscosity calibration curves. It became 20% for the universal calibration curve. LALLS and DV detectors were used together with the DRI detector to provide evidence that the calibration curve deviations were due to the column packings and not due to some other cause (e.g., vendor values of molecular weight). Use of a polynomial fit to a portion of the curve corresponding to the retention volume range of an unknown was used to show the significant improvement in results which occurred when the calibration variations were taken into account. At present, use of many individual narrow standards is necessary to elucidate the effect. © 1990, Taylor & Francis Group, LLC. All rights reserved.
引用
收藏
页码:435 / 452
页数:18
相关论文
共 15 条
  • [1] ALFREDSON TV, 1984, ACS S SER, V245, pCH5
  • [2] Balke S.T., 1984, QUANTITATIVE COLUMN
  • [3] BALKE ST, 1987, ACS S SERIES, V352, pCH12
  • [4] ELUTION VOLUME MEASUREMENT IN SIZE EXCLUSION CHROMATOGRAPHY
    CHAMBERLIN, TA
    TUINSTRA, HE
    [J]. ANALYTICAL CHEMISTRY, 1983, 55 (03) : 428 - 432
  • [5] HANEY MA, 1987, P GPC S 87, P523
  • [6] JANCA J, 1976, J CHROMATOGR, V121, P23
  • [7] HIGH-RESOLUTION PREPARATIVE-SCALE GEL-PERMEATION CHROMATOGRAPHY
    KATO, Y
    KAMETANI, T
    FURUKAWA, K
    HASHIMOTO, T
    [J]. JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 1975, 13 (09) : 1695 - 1703
  • [8] INTERACTION OF RADIAL AND AXIAL-DISPERSION IN LIQUID-CHROMATOGRAPHY IN RELATION TO INFINITE DIAMETER EFFECT
    KNOX, JH
    LAIRD, GR
    RAVEN, PA
    [J]. JOURNAL OF CHROMATOGRAPHY, 1976, 122 (JUL7): : 129 - 145
  • [9] THE ERRORS IN THE TREATMENT OF GEL-PERMEATION CHROMATOGRAPHY DATA - ORIGINS AND CORRECTIONS
    LETOT, L
    LESEC, J
    QUIVORON, C
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1980, 3 (11): : 1637 - 1655
  • [10] THERMAL PULSE TIME-OF-FLIGHT LIQUID FLOW METER
    MILLER, TE