POLY(L-LACTIDE) IMPLANTS IN REPAIR OF DEFECTS OF THE ORBITAL FLOOR - AN ANIMAL STUDY

被引:78
作者
ROZEMA, FR
BOS, RRM
PENNINGS, AJ
JANSEN, HWB
机构
[1] STATE UNIV GRONINGEN,DEPT ORAL & MAXILLOFACIAL SURG,9700 AB GRONINGEN,NETHERLANDS
[2] STATE UNIV GRONINGEN,DEPT POLYMER CHEM,9700 AB GRONINGEN,NETHERLANDS
[3] STATE UNIV GRONINGEN,DEPT HISTOL & CELL BIOL,9700 AB GRONINGEN,NETHERLANDS
关键词
D O I
10.1016/0278-2391(90)90487-M
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Because of the life-long presence of alloplastic, nonresorbable orbital floor implants and the complications of their use mentioned in literature, the use of a resorbable material appears to be preferable in the repair of orbital floor defects. A high-molecular-weight, as-polymerized poly(L-lactide) (PLLA) was used for repair of orbital floor defects of the blowout type in goats. An artificial defect was created in the bony floor of both orbits. Reconstruction of the orbital floor was then carried out using a concave PLLA implant of 0.4-mm thickness. At 3, 6, 12, 19, 26, 52, and 78 weeks postoperatively, one goat was killed. Microscopic examination showed full encapsulation of the implant by connective tissue after 3 weeks. After 6 weeks, resorption and remodeling of the bone at the points of support of the implant could be detected. A differentiation between the sinus and orbital sides of the connective tissue capsule was observed. The orbital side showed a significantly more dense capsule than the antral side, which had a loose appearance. At 19 weeks, a bony plate was progressively being formed, and at 78 weeks, new bone had fully covered the plate on the antral and orbital side. No inflammation or rejection of the PLLA implant was seen. © 1990.
引用
收藏
页码:1305 / 1309
页数:5
相关论文
共 28 条
[1]  
BLEEKER G M, 1959, Ophthalmologica, V138, P40
[2]   RESORBABLE POLY(L-LACTIDE) PLATES AND SCREWS FOR THE FIXATION OF ZYGOMATIC FRACTURES [J].
BOS, RRM ;
BOERING, G ;
ROZEMA, FR ;
LEENSLAG, JW .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1987, 45 (09) :751-753
[3]   BIO-ABSORBABLE PLATES AND SCREWS FOR INTERNAL-FIXATION OF MANDIBULAR FRACTURES - A STUDY IN 6 DOGS [J].
BOS, RRM ;
ROZEMA, FR ;
BOERING, G ;
NIJENHUIS, AJ ;
PENNINGS, AJ ;
VERWEY, AB .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1989, 18 (06) :365-369
[4]   BONE-PLATES AND SCREWS OF BIOABSORBABLE POLY (L-LACTIDE) - AN ANIMAL PILOT-STUDY [J].
BOS, RRM ;
ROZEMA, FR ;
BOERING, G ;
NIJENHUIS, AJ ;
PENNINGS, AJ ;
JANSEN, HWB .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1989, 27 (06) :467-476
[5]  
BOS RRM, 1988, ADV BIOMATER, V8, P245
[6]  
BOS RRM, IN PRESS BIOMATERIAL
[7]  
Brown J. B., 1960, PLAST RECONSTR SURG, V26, P264
[8]  
BURRES SA, 1981, LARYNGOSCOPE, V91, P1881
[9]   ORBITAL BLOWOUT FACTURES - A 10-YEAR SURVEY [J].
CONVERSE, JM ;
SMITH, B ;
OBEAR, MF ;
WOODSMIT.D .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1967, 39 (01) :20-+
[10]   CRITICAL LOOK AT BLOWOUT FRACTURE [J].
CRIKELAIR, GF ;
COSMAN, B ;
POTTER, GD ;
REIN, JM .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1972, 49 (04) :374-+