RADIATION-DOSES FROM NUCLEAR-MEDICINE PATIENTS TO AN IMAGING TECHNOLOGIST - RELATION TO ICRP RECOMMENDATIONS FOR PREGNANT WORKERS

被引:23
作者
CLARKE, EA [1 ]
THOMSON, WH [1 ]
NOTGHI, A [1 ]
HARDING, LK [1 ]
机构
[1] DUDLEY RD GEN HOSP,BIRMINGHAM B18 7QH,W MIDLANDS,ENGLAND
关键词
D O I
10.1097/00006231-199211000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The ICRP has now recommended that the dose limit to the surface of the mother's abdomen during the declared term of pregnancy is reduced to 2 mSv. Direct measurements of the radiation dose to technologists carrying out a variety of imaging studies were made. The average dose ranged from 0.3 muSv for a liver scan to 5.3 muSv for a brain scan. Using national data for the frequency of nuclear medicine studies, a weighted average figure of 1.5 muSv per study was derived. A technologist could therefore perform approximately eight imaging studies per day during the declared term of her pregnancy and remain within the proposed limit. Generally, there should be no need to alter a technologist's duties during her pregnancy, and these findings should be helpful in allaying any anxiety.