ABDOMINAL AORTIC-ANEURYSMS - EVALUATION WITH VARIABLE-COLLIMATION HELICAL CT AND OVERLAPPING RECONSTRUCTION

被引:45
作者
ZEMAN, RK [1 ]
SILVERMAN, PM [1 ]
BERMAN, PM [1 ]
WELTMAN, DI [1 ]
DAVROS, WJ [1 ]
GOMES, MN [1 ]
机构
[1] GEORGETOWN UNIV,MED CTR,DEPT SURG,WASHINGTON,DC 20007
关键词
AORTA; CT; ANEURYSM; ABDOMINAL; COMPUTED TOMOGRAPHY (CT); HELICAL TECHNOLOGY;
D O I
10.1148/radiology.193.2.7972779
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine the value of variable collimation and overlapping reconstruction in helical computed tomography (CT) to evaluate abdominal aortic aneurysm. MATERIALS AND METHODS: Twenty-three patients (15 men and eight women, aged 59-85 years) underwent helical CT scanning, nine with fixed 5-mm collimation and 14 with 3- and 7-mm collimation combined. The ability to visualize main and accessary renal arteries, detect stenoses, and determine aneurysm extent were evaluated. RESULTS: Extent of aneurysm was accurately determined in 17 of 23 cases without overlapping sections; failure to detect ancillary findings such as accessory arteries or stenosis occurred in nine of these cases. With overlapping sections, determination of aneurysm extent improved to 19 of 23 cases and ancillary errors were reduced to four. Five errors occurred with fixed collimation and three errors with variable collimation. CONCLUSION: Overlapping, variable-collimation helical CT allows for a more complete evaluation of abdominal aortic aneurysms than does nonoverlapping, fixed-collimation CT.
引用
收藏
页码:555 / 560
页数:6
相关论文
共 16 条
  • [1] ANGIOGRAPHY IN MANAGEMENT OF ANEURYSMS OF ABDOMINAL-AORTA - ITS VALUE AND SAFETY
    BREWSTER, DC
    RETANA, A
    WALTMAN, AC
    DARLING, RC
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1975, 292 (16) : 822 - 825
  • [2] Darling R C, 1980, World J Surg, V4, P661
  • [3] DIAGNOSIS OF ABDOMINAL AORTIC-ANEURYSMS BY AORTOGRAPHY, COMPUTER-TOMOGRAPHY AND ULTRASOUND
    ERIKSSON, I
    HEMMINGSSON, A
    LINDGREN, PG
    [J]. ACTA RADIOLOGICA-DIAGNOSIS, 1980, 21 (2A): : 209 - 214
  • [4] SPIRAL CT OF THE PANCREAS WITH MULTIPLANAR DISPLAY
    FISHMAN, EK
    WYATT, SH
    NEY, DR
    KUHLMAN, JE
    SIEGELMAN, SS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (06) : 1209 - 1215
  • [5] RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY
    GALANSKI, M
    PROKOP, M
    CHAVAN, A
    SCHAEFER, CM
    JANDELEIT, K
    NISCHELSKY, JE
    [J]. RADIOLOGY, 1993, 189 (01) : 185 - 192
  • [6] GOMES MN, 1979, J CARDIOVASC SURG, V20, P511
  • [7] SPIRAL(HELICAL) CT
    HEIKEN, JP
    BRINK, JA
    VANNIER, MW
    [J]. RADIOLOGY, 1993, 189 (03) : 647 - 656
  • [8] VALUE OF ARTERIOGRAPHY BEFORE ABDOMINAL ANEURYSMECTOMY
    KWAAN, JHM
    CONNOLLY, JE
    VANDERMOLEN, R
    CONROY, R
    [J]. AMERICAN JOURNAL OF SURGERY, 1977, 134 (01) : 108 - 114
  • [9] COMPUTED-TOMOGRAPHY VERSUS AORTOGRAPHY FOR PREOPERATIVE EVALUATION OF ABDOMINAL AORTIC-ANEURYSM
    LARSSON, EM
    ALBRECHTSSON, U
    CHRISTENSON, JT
    [J]. ACTA RADIOLOGICA-DIAGNOSIS, 1984, 25 (02): : 95 - 100
  • [10] PREOPERATIVE EVALUATION OF ABDOMINAL AORTIC-ANEURYSMS BY COMPUTED-TOMOGRAPHY
    PAPANICOLAOU, N
    WITTENBERG, J
    FERRUCCI, JT
    STAUFFER, AE
    WALTMAN, AC
    SIMEONE, JF
    MUELLER, PR
    BREWSTER, PR
    BREWSTER, DC
    DARLING, RC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 146 (04) : 711 - 715