SUPPRESSION OF PLASMA ACTH CONCENTRATION BY ANGIOTENSIN-II INFUSION IN NORMAL HUMANS AND IN A SUBJECT WITH A STEROID 17-ALPHA-HYDROXYLASE DEFECT

被引:43
作者
SEMPLE, PF
BUCKINGHAM, JC
MASON, PA
FRASER, R
机构
[1] WESTERN INFIRM,MRC,BLOOD PRESSURE UNIT,GLASGOW G11 6NT,SCOTLAND
[2] ROYAL FREE HOSP,DEPT PHARMACOL,LONDON,ENGLAND
关键词
D O I
10.1111/j.1365-2265.1979.tb01359.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Six healthy subjects were infused with angiotensin II and plasma concentrations of angiotensin, ACTH and cortisol were measured before, during and after the infusion. In all cases the plasma ACTH concentration fell as plasma angiotensin increased and rose again, sometimes to higher than basal levels, when the angiotensin infusion was terminated. These effects were most marked at the highest rate of infusion (8 pmol/kg/min) and, at the lower rates (2 and 4 pmol/kg/min), there was some recovery of ACTH levels during the infusion period in some subjects. Plasma ACTH concentrations also fell when angiotensin was infused into a patient with high ACTH levels due to a steroid 17α‐hydroxylation defect. The inhibition of ACTH secretion is not due to a rise in plasma cortisol operating a negative feedback inhibition. It could be a direct effect of the infused angiotensin on the brain‐hypothalamus‐pituitary complex or an effect on the metabolism of ACTH. Copyright © 1979, Wiley Blackwell. All rights reserved
引用
收藏
页码:137 / 144
页数:8
相关论文
共 28 条
[1]   CYTOCHEMICAL SECTION ASSAY FOR CORTICOTROPIN [J].
ALAGHBANDZADEH, J ;
DALY, JR ;
BITENSKY, L ;
CHAYEN, J .
CLINICAL ENDOCRINOLOGY, 1974, 3 (03) :319-327
[2]  
BLAIRWEST JR, 1974, ANGIOTENSIN, P337
[3]  
BROWN JJ, 1976, SCOTT MED J, V21, P228
[4]   PRODUCTION OF CORTICOTROPIN RELEASING HORMONE BY ISOLATED HYPOTHALAMUS OF RAT [J].
BUCKINGHAM, JC ;
HODGES, JR .
JOURNAL OF PHYSIOLOGY-LONDON, 1977, 272 (02) :469-479
[5]  
CHAYEN J, 1972, Clinical Endocrinology, V1, P219, DOI 10.1111/j.1365-2265.1972.tb00393.x
[6]   LOSS OF ACTH BIOLOGICAL-ACTIVITY IN PLASMA DURING EXTRACTION WITH A COMMERCIAL RADIOIMMUNOASSAY KIT [J].
COWAN, JS .
CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 1976, 54 (02) :170-171
[7]   ESTIMATION OF ANGIOTENSIN II CONCENTRATION IN HUMAN PLASMA BY RADIOIMMUNOASSAY - SOME APPLICATIONS TO PHYSIOLOGICAL AND CLINICAL STATES [J].
DUSTERDIECK, G ;
MCELWEE, G .
EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 1971, 2 (01) :32-+
[8]   INSULIN AND ADRENOCORTICOTROPIN LABELED WITH RADIO-IODINE [J].
FERREBEE, JW ;
JOHNSON, BB ;
MITHOEFER, JC ;
GARDELLA, JW .
ENDOCRINOLOGY, 1951, 48 (03) :277-283
[9]  
FRASER R, 1965, LANCET, V2, P989
[10]   ASSESSMENT OF 11 BETA-HYDROXYLASE ACTIVITY WITH PLASMA CORTICOSTERONE, DEOXYCORTICOSTERONE, CORTISOL, AND DEOXYCORTISOL - ROLE OF ACTH AND ANGIOTENSIN [J].
GANGULY, A ;
MEIKLE, AW ;
TYLER, FH ;
WEST, CD .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1977, 44 (03) :560-568