LEAKAGE CURRENT REDUCTION FOR A HIGH-FREQUENCY CARRIER INVERTER FEEDING AN INDUCTION-MOTOR

被引:166
作者
MURAI, Y
KUBOTA, T
KAWASE, Y
机构
[1] Department of Electrical Engineering, Gifu University, Gifu
关键词
705 Electric Generators and Motors - 706 Electric Transmission and Distribution - 713 Electronic Circuits - 716 Telecommunication; Radar; Radio and Television - 942 Electric and Electronic Measuring Instruments;
D O I
10.1109/28.148452
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A PWM inverter with an induction motor often has a problem with a leakage current that flows through the distributed electrostatic capacitance from the motor windings to the ground. This paper presents an analytical model of the system with leakage current and the strategy to suppress it. Two types of suppression circuits are discussed. The current-type circuit, although compact in size, not only acts as an excellent suppressor but also becomes a high-performance filter of the output voltage.
引用
收藏
页码:858 / 863
页数:6
相关论文
共 6 条
  • [1] AKAMATU M, 1983, IPEC TOKYO, V2, P1108
  • [2] NISHIMURA T, 1987, ELEC ENG JAPAN, V107, P620
  • [3] Schonung A., 1964, BROWN BOVERI REV, V555
  • [4] SUZUKI I, 1982, TOSHIBA REV, V37, P246
  • [5] UEYAMA N, 1982, NEW DRIVE ELECTRONIC, P100
  • [6] 1980, JIS C8371 JAP IND ST