A FEASIBILITY STUDY ON QUANTITATING MYOCARDIAL PERFUSION WITH ALBUNEX(R), AN ULTRASONIC CONTRAST AGENT

被引:33
作者
WILSON, B
SHUNG, KK
HETE, B
LEVENE, H
BARNHART, JL
机构
[1] PENN STATE UNIV,BIOENGN PROGRAM,231 HALLOWELL BLDG,UNIV PK,PA 16802
[2] MOLEC BIOSYST INC,SAN DIEGO,CA 92121
关键词
ULTRASOUND; ULTRASONIC SCATTERING; INTEGRATED BACKSCATTER; MYOCARDIAL PERFUSION; ULTRASOUND CONTRAST AGENT; ALBUNEX(R);
D O I
10.1016/0301-5629(93)90108-Z
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Quantitating regional myocardial perfusion has been the much sought-after but still elusive goal of many intensive investigations over the years. Videodensitometry of the variation of myocardial echogenicity in two-dimensional (2-D) echocardiograms as a function of time in conjunction with the injection of a bolus of an ultrasound contrast agent has been used clinically as a tool for a direct assessment of regional myocardial perfusion, despite that the precise relationship between tissue echogenicity observed on an image and the echoes detected by the ultrasonic probe is unknown. A study was undertaken to determine whether ultrasonic backscatter calculated from unprocessed radio frequency (RF) echoes returned from myocardium could be used to quantitate regional myocardium perfusion. A real-time ultrasonic scanner has been modified and interfaced to a microcomputer to acquire RF data at a rate up to 10 frames per second. Preliminary experimental data were obtained from four open-chest dogs following intracoronary injection of a bolus of Albunex(R) and two dogs following intravenous injection with this modified scanner. On one hand, these results indicate that the integrated backscatter measured from the region of myocardium perfused by the coronary artery where Albunex(R) is injected and selected for monitoring initially increases, reaches a peak, and then decreases as the contrast agent is washed out and that the magnitude of the peak is approximately linearly proportional to the volume concentration of Albunex(R) microspheres injected, clearly demonstrating the feasibility of this approach for quantitating region myocardial perfusion. On the other hand, intravenous injections did not result in any appreciable change in myocardial backscatter in the left ventricle although a response could be observed in the left ventricular blood pool.
引用
收藏
页码:181 / 191
页数:11
相关论文
共 23 条
[1]  
ARMSTRONG WF, 1986, ECHOCARDIOGR-J CARD, V3, P355
[2]   POSITRON EMISSION TOMOGRAPHY OF THE HEART [J].
BERGMANN, SR ;
FOX, KAA ;
GELTMAN, EM ;
SOBEL, BE .
PROGRESS IN CARDIOVASCULAR DISEASES, 1985, 28 (03) :165-194
[3]  
BLEEKER H, 1990, J ULTRAS MED, V9, P461
[4]   ULTRASONIC CHARACTERIZATION OF ALBUNEX, A NEW CONTRAST AGENT [J].
BLEEKER, HJ ;
SHUNG, KK ;
BARNHART, JL .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 87 (04) :1792-1797
[5]  
DEJONG N, 1991, ULTRASONICS, V30, P95
[6]  
DRESCHEL WR, 1989, THESIS PENNSYLVANIA
[7]   SAFETY AND EFFICACY OF A NEW TRANSPULMONARY ULTRASOUND CONTRAST AGENT - INITIAL MULTICENTER CLINICAL-RESULTS [J].
FEINSTEIN, SB ;
CHEIRIF, J ;
TENCATE, FJ ;
SILVERMAN, PR ;
HEIDENREICH, PA ;
DICK, C ;
DESIR, RM ;
ARMSTRONG, WF ;
QUINONES, MA ;
SHAH, PM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (02) :316-324
[8]  
HEYMANN MA, 1977, PROG CARDIOVASC DIS, V20, P5
[9]   ASSESSMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW WITH MYOCARDIAL CONTRAST TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
KAUL, S ;
KELLY, P ;
OLINER, JD ;
GLASHEEN, WP ;
KELLER, MW ;
WATSON, DD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (02) :468-482
[10]   REVIEW - ASSESSMENT OF MYOCARDIAL PERFUSION WITH CONTRAST 2-DIMENSIONAL ECHOCARDIOGRAPHY [J].
KAUL, S .
AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 1990, 299 (02) :113-130