LOCAL BLOOD RESIDENCE TIMES IN THE PENN STATE ARTIFICIAL-HEART

被引:23
作者
FRANCISCHELLI, DE
TARBELL, JM
GESELOWITZ, DB
机构
[1] PENN STATE UNIV,DEPT CHEM ENGN,155 FENSKE LAB,UNIVERSITY PK,PA 16802
[2] PENN STATE UNIV,BIOENGN PROGRAM,UNIVERSITY PK,PA 16802
关键词
TOTAL ARTIFICIAL HEART; LEFT VENTRICULAR ASSIST DEVICES; THROMBUS FORMATION;
D O I
10.1111/j.1525-1594.1991.tb03042.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Thrombus formation associated with cardiac assist devices is a major concern in their application. Thrombogenesis is thought to be a function of, among other things, fluid shear stress and blood residence time. In the current study, a fiber-optic probe was developed and employed in conjunction with indicator dilution techniques to evaluate the local near-wall fluid residence times at a number of locations inside the Penn State 70 cc parallel port and 100 cc angle port left ventricular assist devices (LVADs). In this in vitro study, both 50% and 30% systolic duration regimes were investigated for each chamber. Using a relatively inexpensive optical arrangement, two decades of dye concentration (10(-6)-10(-4) M of fluorescein sodium) were easily discernible. The washout process was characterized by an exponential decay with a time constant tau. For all positions and operating conditions tested, tau values were between 1-2 beats. In all cases tested, values of tau in the valve regions were significantly longer (8.9-31.6%; p less-than-or-equal-to 0.0075) than in the chamber proper. At every position tau was substantially lower in the 70 cc chamber than in the larger pump (17.8-27.4%). Systolic duration appeared to have no significant effect on tau at the majority of investigated sites. The results indicate that the valve regions, which are known to have greater shear stresses, are also in contact with a volume element of blood for a longer time than is the rest of the chamber. This combination may be detrimental to fragile blood components.
引用
收藏
页码:218 / 224
页数:7
相关论文
共 14 条
  • [1] HOT-FILM WALL SHEAR PROBE MEASUREMENTS INSIDE A VENTRICULAR ASSIST DEVICE
    BALDWIN, JT
    TARBELL, JM
    DEUTSCH, S
    GESELOWITZ, DB
    ROSENBERG, G
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1988, 110 (04): : 326 - 333
  • [2] BALDWIN JT, 1989, T ASAIO, V35, P429
  • [3] BALDWIN JT, 1990, T AM SOC ART INT ORG, V36, P274
  • [4] BLACKSHEAR PS, 1965, ASAIO T, V9, P112
  • [5] THE PERMANENT ARTIFICIAL-HEART - 4 CASE-REPORTS
    DEVRIES, WC
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1988, 259 (06): : 849 - 859
  • [6] DINNAR U, 1981, CARDIOVASCULAR FLUID
  • [7] CARDIAC-OUTPUT MEASUREMENTS - A REVIEW OF CURRENT TECHNIQUES AND RESEARCH
    EHLERS, KC
    MYLREA, KC
    WATERSON, CK
    CALKINS, JM
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1986, 14 (03) : 219 - 239
  • [8] EFFECT OF SHEAR RATE ON CLOT GROWTH AT FOREIGN SURFACES
    HASHIMOTO, S
    MAEDA, H
    SASADA, T
    [J]. ARTIFICIAL ORGANS, 1985, 9 (04) : 345 - 350
  • [9] VISUALIZATION AND ANALYSIS OF MURAL THROMBOGENESIS ON COLLAGEN, POLYURETHANE AND NYLON
    HUBBELL, JA
    MCINTIRE, LV
    [J]. BIOMATERIALS, 1986, 7 (05) : 354 - &
  • [10] RED BLOOD-CELL DAMAGE BY SHEAR-STRESS
    LEVERETT, LB
    LYNCH, EC
    ALFREY, CP
    HELLUMS, JD
    [J]. BIOPHYSICAL JOURNAL, 1972, 12 (03) : 257 - &