SIMPLIFIED DUAL-LUMEN CATHETER DESIGN FOR SIMULTANEOUS POTENTIOMETRIC MONITORING OF CARBON-DIOXIDE AND PH

被引:39
作者
TELTINGDIAZ, M [1 ]
COLLISON, ME [1 ]
MEYERHOFF, ME [1 ]
机构
[1] UNIV MICHIGAN,DEPT CHEM,ANN ARBOR,MI 48109
关键词
D O I
10.1021/ac00076a025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel dual-lumen catheter electrode design suitable for the simultaneous measurement of P-CO2 (partial pressure of carbon dioxide) and pH in flowing blood is described. The probe is fabricated from a single segment of dual-lumen silicone rubber or polyurethane tubing that is impregnated with the proton ionophore tridodecylamine. The impregnation step imparts H+ permselectivity to both inner and outer walls of the tubing. By filling each lumen with a suitable buffer/electrolyte solution and Ag/AgCl reference electrode wire, simultaneous potentiometric detection of both P-CO2 and pH is achieved. Careful optimization of incorporated proton carrier (tridodecylamine), plasticizer (o-nitrophenyl octyl ether), and lipophilic counteranion sites (tetrakis[3,5-bis(trifluoromethyl)phenyl] berate) within the tubing walls yields catheter electrodes with resistance values of 10-20 M Omega and relatively high stability in flowing blood. Results from continuous measurements of P-CO2 and pH during long-term 30-65-h blood loop experiments demonstrate that, after an initial conditioning period, the catheter exhibits low drift rates (P-CO2, 4.7 +/- 1.7 mV/30 h; pH, 1.4 +/- 0.5 mV/30 h) and yields continuously measured values in good agreement with those obtained on discrete samples with a commercial blood gas analyzer (P-CO2, r(2) = 0.997; pH, r(2) = 0.915). In vivo evaluation of the catheter sensors, performed by implanting silicone rubber dual-lumen probes in the arteries of anesthetized dogs, indicates that the proposed catheter design can closely follow P-CO2/pH changes induced in the animals during 6-13 h of continuous monitoring.
引用
收藏
页码:576 / 583
页数:8
相关论文
共 31 条
[1]  
ASHWOOD ER, 1983, CLIN CHEM, V29, P1877
[2]   PROBLEMS WITH THE GAS-CALIBRATED PCO2 ELECTRODE [J].
BATEMAN, NT ;
MUSCH, TI ;
SMITH, CA ;
DEMPSEY, JA .
RESPIRATION PHYSIOLOGY, 1980, 41 (02) :217-226
[3]   INFLUENCE OF ERYTHROCYTES ON DIRECT POTENTIOMETRIC DETERMINATION OF SODIUM AND POTASSIUM [J].
BIJSTER, P ;
VADER, HL ;
VINK, CLJ .
ANNALS OF CLINICAL BIOCHEMISTRY, 1983, 20 (MAR) :116-120
[4]   A NEW MICROELECTRODE METHOD FOR SIMULTANEOUS MEASUREMENT OF PH AND PCO2 [J].
BOMSZTYK, K ;
CALALB, MB .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (05) :F933-F937
[5]   POTENTIOMETRIC COMBINATION ION CARBON-DIOXIDE SENSORS FOR INVITRO AND INVIVO BLOOD MEASUREMENTS [J].
COLLISON, ME ;
AEBLI, GV ;
PETTY, J ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1989, 61 (21) :2365-2372
[6]  
COLLISON ME, 1989, Patent No. 4834101
[7]   EVALUATION OF A DUAL-FUNCTION PH AND PCO-2 INVIVO SENSOR [J].
COON, RL ;
LAI, NCJ ;
KAMPINE, JP .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (04) :625-629
[8]  
FOGT E, 1985, ANAL CHEM, V57, P1157
[9]  
FOGT EJ, 1990, CLIN CHEM, V36, P1573
[10]   OPTICAL FLUORESCENCE AND ITS APPLICATION TO AN INTRAVASCULAR BLOOD-GAS MONITORING-SYSTEM [J].
GEHRICH, JL ;
LUBBERS, DW ;
OPITZ, N ;
HANSMANN, DR ;
MILLER, WW ;
TUSA, JK ;
YAFUSO, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) :117-132