QUANTITATIVE PLANAR IMAGING OF GLUCOSE METABOLIC-ACTIVITY IN MYOCARDIAL SEGMENTS WITH EXERCISE TL-201 PERFUSION DEFECTS IN PATIENTS WITH MYOCARDIAL-INFARCTION - COMPARISON WITH LATE (24-HOUR) REDISTRIBUTION THALLIUM IMAGING FOR DETECTION OF REVERSIBLE ISCHEMIA

被引:21
作者
WILLIAMS, KA [1 ]
TAILLON, LA [1 ]
STARK, VJ [1 ]
机构
[1] UNIV CHICAGO, DEPT RADIOL NUCL MED, CHICAGO, IL 60601 USA
关键词
D O I
10.1016/0002-8703(92)90590-R
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Exercise thallium-201 24-hour redistribution imaging and myocardial glucose metabolism with F-18-deoxyglucose were used to identify reversible ischemia in 30 patients with previous myocardial infarction. Metabolic images were obtained using a planar gamma camera fitted with a rotating tungsten collimator. Of 184 exercise thallium perfusion defects, late redistribution occurred in 88. Metabolic evidence for reversibility (metabolism-perfusion mismatch) was identified in 91% of these 24-hour reversible segments. However, 72% of the segments with fixed perfusion defects also had residual ischemia by F-18-deoxyglucose. Out of 26 fixed severe thallium defects, 69%. had F-18-deoxyglucose evidence for residual ischemia. A subset of 14 patients underwent serial exercise thallium scintigraphy or gated equilibrium radionuclide angiography after revascularization or medical therapy. Out of 46 fixed thallium defects in these patients, 30 demonstrated serial scintigraphic improvement. F-18-deoxyglucose-thallium mismatch was present in 81% of these segments, but was absent in the majority of the unimproved segments. Thus quantitative planar imaging of myocardial glucose metabolism with F-18-deoxyglucose using a well-collimated gamma camera can detect clinically important reversible ischemia in segments with fixed thallium defects at late redistribution imaging.
引用
收藏
页码:294 / 304
页数:11
相关论文
共 25 条
[1]   IDENTIFICATION OF VIABLE MYOCARDIUM IN PATIENTS WITH CHRONIC CORONARY-ARTERY DISEASE AND LEFT-VENTRICULAR DYSFUNCTION - COMPARISON OF THALLIUM SCINTIGRAPHY WITH REINJECTION AND PET IMAGING WITH F-18 FLUORODEOXYGLUCOSE [J].
BONOW, RO ;
DILSIZIAN, V ;
CUOCOLO, A ;
BACHARACH, SL .
CIRCULATION, 1991, 83 (01) :26-37
[2]   POSITRON EMISSION TOMOGRAPHY DETECTS TISSUE METABOLIC-ACTIVITY IN MYOCARDIAL SEGMENTS WITH PERSISTENT THALLIUM PERFUSION DEFECTS [J].
BRUNKEN, R ;
SCHWAIGER, M ;
GROVERMCKAY, M ;
PHELPS, ME ;
TILLISCH, J ;
SCHELBERT, HR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (03) :557-567
[3]   PET DETECTION OF VIABLE TISSUE IN MYOCARDIAL SEGMENTS WITH PERSISTENT DEFECTS AT T1-201 SPECT [J].
BRUNKEN, RC ;
KOTTOU, S ;
NIENABER, CA ;
SCHWAIGER, M ;
RATIB, OM ;
PHELPS, ME ;
SCHELBERT, HR .
RADIOLOGY, 1989, 172 (01) :65-73
[4]  
BRUNKEN RC, 1988, CIRCULATION S2, V78, P91
[5]   INCOMPLETE REDISTRIBUTION IN DELAYED TL-201 SINGLE PHOTON-EMISSION COMPUTED TOMOGRAPHIC (SPECT) IMAGES - AN OVERESTIMATION OF MYOCARDIAL SCARRING [J].
CLONINGER, KG ;
DEPUEY, EG ;
GARCIA, EV ;
ROUBIN, GS ;
ROBBINS, WL ;
NODY, A ;
DEPASQUALE, EE ;
BERGER, HJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (04) :955-963
[6]  
Colton T., 1974, STAT MED, P151
[7]   ENHANCED DETECTION OF ISCHEMIC BUT VIABLE MYOCARDIUM BY THE REINJECTION OF THALLIUM AFTER STRESS REDISTRIBUTION IMAGING [J].
DILSIZIAN, V ;
ROCCO, TP ;
FREEDMAN, NMT ;
LEON, MB ;
BONOW, RO .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (03) :141-146
[8]   PROSPECTIVE ASSESSMENT OF REGIONAL MYOCARDIAL PERFUSION BEFORE AND AFTER CORONARY REVASCULARIZATION SURGERY BY QUANTITATIVE TL-201 SCINTIGRAPHY [J].
GIBSON, RS ;
WATSON, DD ;
TAYLOR, GJ ;
CROSBY, IK ;
WELLONS, HL ;
HOLT, ND ;
BELLER, GA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 1 (03) :804-815
[9]  
GOULD KL, 1989, J NUCL MED, V30, P707
[10]   LATE REVERSIBILITY OF TOMOGRAPHIC MYOCARDIAL TL-201 DEFECTS - AN ACCURATE MARKER OF MYOCARDIAL VIABILITY [J].
KIAT, H ;
BERMAN, DS ;
MADDAHI, J ;
DEYANG, L ;
VANTRAIN, K ;
ROZANSKI, A ;
FRIEDMAN, J .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (06) :1456-1463