GADOLINIUM-ENHANCED HIGH-RESOLUTION MR ANGIOGRAPHY WITH ADAPTIVE VESSEL TRACKING - PRELIMINARY-RESULTS IN THE INTRACRANIAL CIRCULATION

被引:54
作者
LIN, WL
HAACKE, EM
SMITH, AS
CLAMPITT, ME
机构
[1] Department of Biomedical Engineering, Case Western Reserve University, Cleveland
[2] Department of Physics, Case Western Reserve University, Cleveland
[3] Department of Radiology, MRI, University Hospitals of Cleveland, Cleveland, Ohio, 44106
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1992年 / 2卷 / 03期
关键词
CEREBRAL BLOOD VESSELS; MR; CONTRAST ENHANCEMENT; GADOLINIUM; HIGH-RESOLUTION IMAGING; IMAGE PROCESSING; PULSE SEQUENCES; RECONSTRUCTION ALGORITHMS; VASCULAR STUDIES;
D O I
10.1002/jmri.1880020305
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To overcome problems associated with poor contrast between vessels and background tissue in time-of-flight magnetic resonance angiography, the role of intravenous gadopentetate dimeglumine in conjunction with a postprocessing adaptive vessel tracking scheme was studied. Vessel tracking makes it possible to discriminate arteries from veins, to prevent problems associated with other bright tissues on maximum-intensity projections, and to increase the signal-to-noise ratio. Short, asymmetric, velocity-compensated field echoes were used in conjunction with high-resolution imaging techniques to spatially discriminate between adjacent vessels and stationary background tissue. Gadopentetate dimeglumine was shown to be useful for visualization of small vessels, aneurysms, and regions of slow flow, when used with this post-processing scheme.
引用
收藏
页码:277 / 284
页数:8
相关论文
共 24 条
  • [1] Haacke EM, Masaryk TJ, Wielopolski P, Et al., Optimizing blood vessel contrast in fast three‐dimensional magnetic resonance imaging, Magn Reson Med, 14, pp. 202-221, (1990)
  • [2] Schmalbrock P, Yuan C, Chakeres DW, Kohli J, Pelc NJ, Volume MR angiography: methods to achieve very short echo times, Radiology, 175, pp. 861-865, (1990)
  • [3] Lin W, Haacke EM, Short field‐echo sequences with partial Fourier reconstruction to avoid signal loss and blurring in MR angiography (abstr), Radiology, 177, P, (1990)
  • [4] Creasy JL, Price RR, Presbrey T, Goins D, Partain CL, Kessler RM, Gadolinium‐enhanced MR angiography, Radiology, 175, pp. 280-283, (1990)
  • [5] Seiderer M, Bauer WM, Villringer A, Einhaupl K, 3D‐MR‐angiographie mit Gd‐DTPA, ROFO, 152, pp. 327-332, (1990)
  • [6] Blatter DD, Parker DL, Robison RO, Cerebral MR angiography with multiple overlapping thin slab acquisition. I. Quantitative analysis of vessel visibility, Radiology, 179, pp. 805-812, (1991)
  • [7] Haacke EM, Lindskog E, Lin W, pp. 126-145, (1991)
  • [8] MacFall JR, Pelc NJ, Vaverk RM, Correction of spatially dependent phase shifts for partial Fourier imaging, Magn Reson Imaging, 6, pp. 143-155, (1988)
  • [9] Haacke EM, Liang ZP, Boada F, Image reconstruction using projection onto convex sets, model constraints, and linear prediction theory for the removal of phase, motion, and Gibbs artifacts in magnetic resonance and ultrasound imaging, Opt Eng, 29, pp. 555-566, (1990)
  • [10] Haacke EM, Lenz GW, Improving image quality in the presence of motion by using rephasing gradients, AJR, 148, pp. 1251-1258, (1987)