HIGH-PERFORMANCE FLOW ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY FOR ONLINE TRACE-ELEMENT PRECONCENTRATION-MATRIX SEPARATION AND TRACE-ELEMENT DETERMINATION

被引:19
作者
BERNDT, H
SCHALDACH, G
机构
关键词
HYDRAULIC HIGH-PRESSURE NEBULIZATION; ELECTROTHERMAL ATOMIC ABSORPTION SPECTROMETRY; SAMPLE INTRODUCTION; ONLINE MATRIX SEPARATION; PRECONCENTRATION;
D O I
10.1039/ja9940900039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
With the aerosol deposition module (ADM) the samples to be analysed by electrothermal atomic absorption spectrometry (ETAAS) are carried as an aerosol into the graphite tube and deposited at about 140-degrees-C. The ADM is normally equipped with a pneumatic nebulizer, but in this work this is replaced by a hydraulic high-pressure (HHP) nebulizer. If HHP nebulization is used to produce the aerosol, the efficiency of aerosol transport is substantially improved (maximum aerosol yield, 60%). As a high-pressure flow system is required for this type of nebulization, on-line matrix separations-trace element preconcentrations for ETAAS are also possible. The trace elements can be separated on-line from aluminium solutions (AlCl3) and determined in 4 min. Detection limits are in the ng g-1 range (as trace elements in the aluminium). In comparison with the original ADM for sample introduction, the detection power is improved by about two orders of magnitude.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 15 条
[1]  
[Anonymous], COMMUNICATION
[2]   MICRODETERMINATION BY ATOMIC-ABSORPTION SPECTROMETRY AND ANALYSIS OF TRACE-ELEMENT CONCENTRATE BY INJECTION METHOD [J].
BERNDT, H ;
JACKWERTH, E .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1975, 30 (05) :169-177
[3]   REDUCTION OF MATRIX INTERFERENCES AND IMPROVEMENT OF DETECTION POWER IN FLAME AAS BY A HIGH-PERFORMANCE FLOW HYDRAULIC HIGH-PRESSURE NEBULIZATION SYSTEM FOR SAMPLE INTRODUCTION (HPF/HHPN) - TRACE-ELEMENT DETERMINATION IN ALUMINUM, IRON AND COPPER [J].
BERNDT, H ;
MULLER, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 345 (01) :18-24
[4]   HIGH-PRESSURE NEBULIZATION - A NEW WAY OF SAMPLE INTRODUCTION FOR ATOMIC SPECTROSCOPY [J].
BERNDT, H .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 331 (3-4) :321-323
[5]   ONLINE TRACE PRECONCENTRATION MATRIX SEPARATION BY HIGH-PERFORMANCE FLOW ATOMIC SPECTROMETRY (HPF-FLAME AAS) - TRACE DETERMINATION IN ALUMINUM AND IN DRINKING-WATER [J].
BERNDT, H ;
MULLER, A ;
SCHALDACH, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (6-9) :711-716
[6]  
BERNDT H, 1989, CHEM LABOR BETR, V40, P299
[7]   JET-IMPACT NEBULIZATION FOR SAMPLE INTRODUCTION IN INDUCTIVELY COUPLED PLASMA SPECTROMETRY [J].
DOHERTY, MP ;
HIEFTJE, GM .
APPLIED SPECTROSCOPY, 1984, 38 (03) :405-412
[8]  
HERRMANN R, 1960, FLAMMENPHOTOMETRIE, P92
[9]   CONTINUOUS SAMPLE INTRODUCTION WITH GRAPHITE ATOMIZATION SYSTEMS FOR ATOMIC-ABSORPTION SPECTROMETRY [J].
KANTOR, T ;
CLYBURN, SA ;
VEILLON, C .
ANALYTICAL CHEMISTRY, 1974, 46 (14) :2205-2213
[10]  
KOCH OG, 1974, HDB SPURENANALYSE 1, P297