Measurement of coronary artery stenosis is an invaluable tool in the study of coronary artery disease. Clinical trials and even day-to-day decision making should ideally be based on accurate and reproducible quantitative methods. Quantitative coronary angiography (QCA) using digital angiographic techniques has been shown to fulfill these requirements. Yet many laboratories have abandoned visual analysis in favor of the intermediate quantitative approach involving hand-held calipers. Thus, the purpose of this study was to determine the relation between QCA and the commonly used caliper measurements. Percent stenosis was assessed in 155 lesions using 3 techniques: QCA, caliper measures from a 35-mm cine viewer (cine) and caliper measures from a video display (CRT). Good overall correlation was noted among the 3 different techniques (r >-0.72). Both of the caliper methods underestimated QCA for stenosis ≥75% (p ≤0.001) and overestimated stenosis <75% (p < 0.05). Reproducibility assessed in 52 lesions by independent observers showed QCA to be superior (r = 0.95) to either of the caliper measurements (cine: r = 0.63; CRT: r = 0.73). Therefore, the commonly used caliper method is not an adequate substitute for QCA because overestimation of noncritical stenoses and underestimation of severe stenoses may occur and the measurements have poor reproducibility. These factors definitely preclude its use in rigorous clinical trials. Moreover, since they do not appear to overcome known deficiencies of visual analysis, caliper measurements for day-to-day clinical use must also be seriously questioned. © 1990.
引用
收藏
页码:1181 / 1184
页数:4
相关论文
共 30 条
  • [1] CORONARY-ARTERY NARROWING IN CORONARY HEART-DISEASE - COMPARISON OF CINEANGIOGRAPHIC AND NECROPSY FINDINGS
    ARNETT, EN
    ISNER, JM
    REDWOOD, DR
    KENT, KM
    BAKER, WP
    ACKERSTEIN, H
    ROBERTS, WC
    [J]. ANNALS OF INTERNAL MEDICINE, 1979, 91 (03) : 350 - 356
  • [2] DIGITAL SUBTRACTION CORONARY ANGIOGRAPHY USING HIGH-PASS TEMPORAL FILTRATION - A COMPARISON WITH CINEANGIOGRAPHY
    BRAY, BE
    ANDERSON, FL
    HARDIN, CW
    KRUGER, RA
    SUTTON, RB
    NELSON, JA
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1985, 11 (01): : 17 - 24
  • [3] QUANTITATIVE CORONARY ARTERIOGRAPHY - ESTIMATION OF DIMENSIONS, HEMODYNAMIC RESISTANCE, AND ATHEROMA MASS OF CORONARY-ARTERY LESIONS USING ARTERIOGRAM AND DIGITAL COMPUTATION
    BROWN, BG
    BOLSON, E
    FRIMER, M
    DODGE, HT
    [J]. CIRCULATION, 1977, 55 (02) : 329 - 337
  • [4] BROWN BG, 1986, PROG CARDIOVASC DIS, V28, P403
  • [5] VARIABILITY IN ANALYSIS OF CORONARY ARTERIOGRAMS
    DEROUEN, TA
    MURRAY, JA
    OWEN, W
    [J]. CIRCULATION, 1977, 55 (02) : 324 - 328
  • [6] OBSERVER AGREEMENT IN EVALUATING CORONARY ANGIOGRAMS
    DETRE, KM
    WRIGHT, E
    MURPHY, ML
    TAKARO, T
    [J]. CIRCULATION, 1975, 52 (06) : 979 - 986
  • [7] REPRODUCIBILITY OF CORONARY ARTERIOGRAPHIC READING IN THE CORONARY-ARTERY SURGERY STUDY (CASS)
    FISHER, LD
    JUDKINS, MP
    LESPERANCE, J
    CAMERON, A
    SWAYE, P
    RYAN, T
    MAYNARD, C
    BOURASSA, M
    KENNEDY, JW
    GOSSELIN, A
    KEMP, H
    FAXON, D
    WEXLER, L
    DAVIS, KB
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1982, 8 (06): : 565 - 575
  • [8] DIAGNOSTIC-ACCURACY OF CORONARY ANGIOGRAPHY UTILIZING COMPUTER-BASED DIGITAL SUBTRACTION METHODS - COMPARISON TO CONVENTIONAL CINEANGIOGRAPHY
    GOLDBERG, HL
    MOSES, JW
    FISHER, J
    TAMARI, I
    BORER, JS
    [J]. CHEST, 1986, 90 (06) : 793 - 797
  • [9] GRONDIN CM, 1974, CIRCULATION, V49, P703
  • [10] COMPARISON OF SIMULTANEOUSLY PERFORMED DIGITAL AND FILM-BASED ANGIOGRAPHY IN ASSESSMENT OF CORONARY-ARTERY DISEASE
    GURLEY, JC
    NISSEN, SE
    BOOTH, DC
    HARRISON, M
    GRAYBURN, P
    ELION, JL
    DEMARIA, AN
    [J]. CIRCULATION, 1988, 78 (06) : 1411 - 1420