MEASUREMENT OF IONS WITHIN A PULSED ELECTRON-CAPTURE DETECTOR BY MASS-SPECTROMETRY

被引:44
作者
GRIMSRUD, EP
KIM, SH
GOBBY, PL
机构
[1] Department of Chemistry, Montana State University, Bozeman
关键词
D O I
10.1021/ac50038a017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Measurements of ions within an electron capture detector (ECD) have been made by the technique of atmospheric pressure ionization mass spectrometry (APIMS) where the ion source has been modified to be an actual ECD. By observing the dependence of ion signals on electrostatic fields applied to the ionization cell, new insight into the role of ions in influencing the measured ECD current is provided. It is shown that for this pulsed ECD, a positive current of significant magnitude exists which is an integral component of the normally measured ECD current, that it is caused by the selective migration of positive ions to the sampling electrode during the period between pulses. The results are discussed relative to opposing views of the ECD, are shown to strongly support one of these. © 1979, American Chemical Society. All rights reserved.
引用
收藏
页码:223 / 229
页数:7
相关论文
共 26 条
  • [1] ELECTRON-CAPTURE DETECTOR - CONTROVERSIES, COMMENTS, AND CHROMATOGRAMS
    AUE, WA
    KAPILA, S
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1973, 11 (05) : 255 - 263
  • [2] SUBPICOGRAM DETECTION SYSTEM FOR GAS-PHASE ANALYSIS BASED UPON ATMOSPHERIC-PRESSURE IONIZATION (API) MASS-SPECTROMETRY
    CARROLL, DI
    DZIDIC, I
    STILLWELL, RN
    HORNING, MG
    HORNING, EC
    [J]. ANALYTICAL CHEMISTRY, 1974, 46 (06) : 706 - 710
  • [3] VARIATIONS OF RESPONSE FACTORS OF ELECTRON CAPTURE DETECTOR WITH VARIOUS PARAMETERS
    DEVAUX, P
    GUIOCHON, G
    [J]. JOURNAL OF GAS CHROMATOGRAPHY, 1967, 5 (07): : 341 - &
  • [4] ATMOSPHERIC-PRESSURE IONIZATION (API) MASS-SPECTROMETRY - FORMATION OF PHENOXIDE IONS FROM CHLORINATED AROMATIC-COMPOUNDS
    DZIDIC, I
    CARROLL, DI
    STILLWELL, RN
    HORNING, EC
    [J]. ANALYTICAL CHEMISTRY, 1975, 47 (08) : 1308 - 1312
  • [5] LINEAR ELECTRON CAPTURE DETECTION
    FENIMORE, DC
    DAVIS, CM
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1970, 8 (09) : 519 - &
  • [6] VACUUM ENVELOPE FOR HIGH-PRESSURE MASS-SPECTROMETRY APPLICATIONS
    GRIMSRUD, E
    [J]. ANALYTICAL CHEMISTRY, 1978, 50 (02) : 382 - 384
  • [7] EFFECT OF OXYGEN ON RESPONSE OF A CONSTANT-CURRENT NI-63 ELECTRON-CAPTURE DETECTOR
    GRIMSRUD, EP
    STEBBINS, RG
    [J]. JOURNAL OF CHROMATOGRAPHY, 1978, 155 (01): : 19 - 34
  • [8] PRODUCTS FROM ELECTRON-CAPTURE REACTIONS
    HASTINGS, CR
    RYAN, TR
    AUE, WA
    [J]. ANALYTICAL CHEMISTRY, 1975, 47 (07) : 1169 - 1173
  • [9] ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY - STUDIES OF NEGATIVE-ION FORMATION FOR DETECTION AND QUANTIFICATION PURPOSES
    HORNING, EC
    CARROLL, DI
    DZIDIC, I
    LIN, SN
    STILLWELL, RN
    THENOT, JP
    [J]. JOURNAL OF CHROMATOGRAPHY, 1977, 142 (NOV): : 481 - 495
  • [10] EFFECT OF OXYGEN ON RESPONSE OF ELECTRON-CAPTURE DETECTOR
    KARASEK, FW
    KANE, DM