ANODIC-STRIPPING VOLTAMMETRY AT MERCURY FILMS DEPOSITED ON ULTRASMALL CARBON-RING ELECTRODES

被引:31
作者
WONG, DKY [1 ]
EWING, AG [1 ]
机构
[1] PENN STATE UNIV,DEPT CHEM,152 DAVEY LAB,UNIVERSITY PK,PA 16802
关键词
D O I
10.1021/ac00223a010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Anodic stripping voltammetry of lead and cadmium without deliberately added electrolytes has been studied at ultrasmall carbon-ring electrodes following In situ deposition of mercury. The stripping of lead has been studied In detail to Investigate the dependence of stripping peak current on experimental parameters such as potential scan rate, preconcentration duration, deposition potential, concentration of Hg+ during deposition, and concentration of Pb2+. Anodic stripping voltammetry In solutions without deliberately added supporting electrolyte avoids problems associated with Impurities Introduced when electrolyte Is added. These Impurities appear to be highly Important when Pb2+ analysis Is carried out In dilute solutions. In addition, a unique effect is observed when relatively low concentrations of Hg+ (1.0 × 10−6 M) are used for the In situ deposition step. When low Hg+ concentrations are used, the stripping current does not decrease as rapidly as expected as the concentration of Pb2+ is reduced. The slope of the log-log plot of peak current vs Pb2+ concentration is significantly less than unity, but the calibration plot Is linear, and the resulting enhanced peak currents at low Pb2+ concentrations make stripping analysis possible at extremely low concentrations. Concentrations as low as 3.2 × 10−11 M of Pb2+ have been examined. © 1990 American Chemical Society. All rights reserved.
引用
收藏
页码:2697 / 2702
页数:6
相关论文
共 32 条
  • [1] AUTOMATED-DETERMINATION OF CADMIUM AND LEAD IN WHOLE-BLOOD BY COMPUTERIZED FLOW POTENTIOMETRIC STRIPPING WITH CARBON-FIBER ELECTRODES
    ALMESTRAND, L
    JAGNER, D
    RENMAN, L
    [J]. ANALYTICA CHIMICA ACTA, 1987, 193 : 71 - 79
  • [2] ULTRAMICROELECTRODES - CYCLIC VOLTAMMETRY ABOVE ONE MILLION V-S-1
    ANDRIEUX, CP
    GARREAU, D
    HAPIOT, P
    SAVEANT, JM
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 248 (02): : 447 - 450
  • [3] [Anonymous], 1985, STRIPPING ANAL PRINC
  • [4] RAPID ANODIC-STRIPPING ANALYSIS WITH ULTRAMICROELECTRODES
    BARANSKI, AS
    [J]. ANALYTICAL CHEMISTRY, 1987, 59 (04) : 662 - 666
  • [5] DIFFUSIONAL IMPEDANCE OF STATIONARY MICROELECTRODES
    BEZEGH, A
    JANATA, J
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 215 (1-2): : 139 - 149
  • [6] AN EVALUATION OF ULTRATHIN RING AND BAND MICROELECTRODES AS AMPEROMETRIC SENSORS IN ELECTROCHEMICAL FLOW CELLS
    BIXLER, JW
    FIFIELD, M
    POLER, JC
    BOND, AM
    THORMANN, W
    [J]. ELECTROANALYSIS, 1989, 1 (01) : 23 - 33
  • [7] ELECTROCHEMISTRY IN ORGANIC-SOLVENTS WITHOUT SUPPORTING ELECTROLYTE USING PLATINUM MICROELECTRODES
    BOND, AM
    FLEISCHMANN, M
    ROBINSON, J
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 168 (1-2): : 299 - 312
  • [8] THE USE OF PLATINUM MICROELECTRODES FOR ELECTROCHEMICAL INVESTIGATIONS IN LOW-TEMPERATURE GLASSES OF NON-AQUEOUS SOLVENTS
    BOND, AM
    FLEISCHMANN, M
    ROBINSON, J
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 180 (1-2): : 257 - 263
  • [9] FARADAIC ELECTROCHEMISTRY AT MICRO-VOLTAMMETRIC ELECTRODES
    DAYTON, MA
    BROWN, JC
    STUTTS, KJ
    WIGHTMAN, RM
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (06) : 946 - 950
  • [10] PULSE VOLTAMMETRY WITH MICROVOLTAMMETRIC ELECTRODES
    EWING, AG
    DAYTON, MA
    WIGHTMAN, RM
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (12) : 1842 - 1847