RISK-FACTORS FOR CONTAMINATION OF DOMESTIC HOT WATER-SYSTEMS BY LEGIONELLAE

被引:92
作者
ALARY, M
JOLY, JR
机构
[1] UNIV LAVAL,FAC MED,DEPT MICROBIOL,QUEBEC CITY G1K 7P4,QUEBEC,CANADA
[2] UNIV LAVAL,DEPT MED SOCIALE & PREVENT,QUEBEC CITY G1K 7P4,QUEBEC,CANADA
关键词
D O I
10.1128/AEM.57.8.2360-2367.1991
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
To assess risk factors associated with the contamination of the domestic environment by legionellae, 211 houses in the Quebec City area were randomly selected and water samples were collected from the hot water tank, the shower heads, and the most frequently used faucet. After centrifugation, concentrated samples were seeded in triplicate on BCYE and GPV media. Data on the characteristics of the hot water system and plumbing in the house and on the personal habits of the occupants were collected for each house. Among these 211 houses, hot water was provided by either an oil or gas heater in 33 and by an electric heater in 178. Legionellae were isolated from none of the samples from houses with oil or gas heaters and from 39% (69 of 178) of those with electric water heaters (P < 0.0001). This association remained highly significant after control for water temperature and other variables in a stratified analysis. In the 178 houses with an electric heater, 12% of the faucets, 15% of the shower heads, and 37% of the water heaters were contaminated. Legionella pneumophila serogroups 2 and 4 were the most frequently isolated strains. Logistic regression showed that factors associated with electric water heater contamination were (i) location of the house in older districts of the city (P < 0.0001), (ii) old age of the water heater (P = 0.003), and (iii) low water temperature (P = 0.05). Contamination of the water heater was the only factor significantly associated with the contamination of peripheral outlets (P < 0.0001). This study shows that the presence of an electric heater is strongly associated with contamination of domestic hot water systems by Legionellae. The public health importance of this contamination is still unknown.
引用
收藏
页码:2360 / 2367
页数:8
相关论文
共 52 条
[1]  
BARTLETT CLR, 1983, LANCET, V2, P1315
[2]  
BORNSTEIN N, 1986, ISRAEL J MED SCI, V22, P655
[3]   ASSOCIATION OF SHOWER USE WITH LEGIONNAIRES-DISEASE - POSSIBLE ROLE OF AMEBAS [J].
BREIMAN, RF ;
FIELDS, BS ;
SANDEN, GN ;
VOLMER, L ;
MEIER, A ;
SPIKA, JS .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1990, 263 (21) :2924-2926
[4]   ROLE OF STAGNATION AND OBSTRUCTION OF WATER-FLOW IN ISOLATION OF LEGIONELLA-PNEUMOPHILA FROM HOSPITAL PLUMBING [J].
CIESIELSKI, CA ;
BLASER, MJ ;
WANG, WLL .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1984, 48 (05) :984-987
[5]  
COLBOURNE JS, 1989, J INST WATER ENV MAN, V3, P345
[6]   LEGIONELLA AND PUBLIC WATER-SUPPLIES [J].
COLBOURNE, JS ;
DENNIS, PJ ;
TREW, RM ;
BERRY, C ;
VESEY, G .
WATER SCIENCE AND TECHNOLOGY, 1988, 20 (11-12) :5-10
[7]  
DENNIS PJ, 1982, LANCET, V1, P949
[8]   LEGIONELLA-PNEUMOPHILA IN AEROSOLS FROM SHOWER BATHS [J].
DENNIS, PJL ;
WRIGHT, AE ;
RUTTER, DA ;
DEATH, JE ;
JONES, BPC .
JOURNAL OF HYGIENE, 1984, 93 (02) :349-353
[9]  
DESPLACES N, 1984, PRESSE MED, V13, P1875
[10]   CONTAMINATION OF DOMESTIC WATER-HEATERS WITH LEGIONELLA-PNEUMOPHILA - IMPACT OF WATER TEMPERATURE ON GROWTH AND DISSEMINATION OF THE BACTERIUM [J].
DEWAILLY, E ;
JOLY, JR .
ENVIRONMENTAL TOXICOLOGY AND WATER QUALITY, 1991, 6 (02) :249-257